FAQ within [ Drive Products ]
-
Check the AU signal (AU - SD). To use the terminal 4, the AU signal (AU - SD) needs to be turned ON. Turning ON the AU signal (AU - SD) disables the terminal 2. More Details >>
- No:21267
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
There are two methods to reduce the running frequency variation. 1. Increase the setting value of Pr.74 (Input filter time constant) to reduce the variation.... More Details >>
- No:21296
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
When Pr.79 is set to "3", the JOG operation is not available by turning ON the terminal JOG.Instead of the JOG function, you can set the low-speed RL of the ... More Details >>
- No:21760
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Circuit type of the FR-D700W/FR-E700W in the harmonics suppression guideline
It is single-phase bridge (smoothing capacitor, double voltage rectification). More Details >>
- No:20864
- Release Date:2018/08/22 16:24
- Category: FREQROL-E700
-
Yes. More Details >>
- No:21034
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Normally, any of the PU, EXT, or NET LED turns ON.Check if the parameter unit FR-PU04/FR-PU07 or operation panel FR-PA07 is externally connected to the PU co... More Details >>
- No:21803
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
External multi-speed setting and multi-speed command
It depends on the setting of Pr.79 (Operation mode).Pr.79 can be set to "2" or "3".If Pr.79 is "2", it is judged that the multi-speed frequency command was s... More Details >>
- No:21815
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Setting dial and FR-PA02 built-in potentiometer
When the FR-PA02 is connected to the inverter with a cable, the FR-PA02 becomes effective.The operation panel of the inverter can also be used to set some pa... More Details >>
- No:21861
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-F700PJ
-
The following version or later is supported for Windows 8. MR Configurator2, 1.20W or later More Details >>
- No:23633
- Release Date:2018/09/14 15:10
- Category: Servo Support Software
-
The machine analyzer analyzes the machine frequency characteristic and calculates the frequency of machine resonance suppression filter by measuring the res... More Details >>
- No:23656
- Release Date:2018/09/14 15:10
- Category: Servo Support Software