FAQ within [ Drive Products ]
-
Yes, the circuit board coating and conductive plating are applied to the HC2 as standard. More Details >>
- No:21026
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Turning ON the main circuit power stops the 24 V external power supply operation and enables the normal operation. Therefore, the separate power supply canno... More Details >>
- No:21018
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
The ON level is the power supply voltage -3 V or higher and the OFF level is 3 V or lower. More Details >>
- No:21002
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , Plug-in Options
-
When the online auto tuning (magnetic field observer) is enabled, the monitoring accuracy is ± 10%. More Details >>
- No:20981
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
Vector control cannot be selected unless Pr.862 is set to 1. (Only the first motor is supported in the motor setting of FR Configurator2.) More Details >>
- No:20908
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
High speed sampling of FR Configurator2
High speed sampling is not available. Only the normal sampling is available. More Details >>
- No:20848
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
Yes. More Details >>
- No:20810
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Others
-
- No:23649
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
Check if the communication setting parameters (Pr.117 to Pr.124) are set to the same values between the inverter and personal computer.Note that communicatio... More Details >>
- No:22105
- Release Date:2018/08/22 16:31
- Category: Inverters-FREQROL , FREQROL-A500
-
If the MC on the input side is shut off using the fault output of the FR-E500, the inverter's fault records are left in the faults history. More Details >>
- No:22096
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500