Turn ON and OFF the RES signal to enable the inverter-driven operation. More Details >>
- No:21190
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
The value of Pr.20 (Acceleration/deceleration standard frequency) is corresponding to 1 s. (Initial value: 60 Hz) More Details >>
- No:21185
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Check the setting value of Pr.37 (Speed display). When the machine speed is set, Pr.811 is disabled. Change the setting to the rotation speed. More Details >>
- No:21161
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
Since the FR-HC2 switches the TRM according to the power supply phase, it has a circuit that detects the power supply phase. "A phase is confirmed" when the ... More Details >>
- No:21154
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
It is set to "1" (cooling fan ON-OFF control enabled). More Details >>
- No:21131
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-F700PJ
-
Parts arrangement is available. Consult with your sales agent. More Details >>
- No:21129
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
No. (Using the copy function causes an error.) Use the FR-DU08 when performing the copy function of the operation panel. More Details >>
- No:21118
- Release Date:2018/08/22 16:26
- Category: FREQROL-A800 , Options , FREQROL-F800
-
They can be compliant by connecting an optional DC reactor (FR-HEL). (A capacitive filter and common mode choke are built in (the common mode choke is provid... More Details >>
- No:21117
- Release Date:2018/08/22 16:26
- Category: FREQROL-A800 , FREQROL-F800
-
When Pr.414 is set to "1" and Pr.388 is set to "0", the PLC function is not enabled unless both the SQ signal from communication and the SQ signal from the e... More Details >>
- No:21073
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
The output of the FM terminal becomes the current output of the CA. More Details >>
- No:21060
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , Options