FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Check the parameters listed below necessary for tuning again.Pr.9, Pr.71, Pr.80, Pr.81, Pr.83, Pr.84, and Pr.96 More Details >>
- No:21726
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
The FR-E700 series is not equipped with the EMC filter. More Details >>
- No:21667
- Release Date:2018/08/22 16:28
- Category: FREQROL-E700
-
What happens if the supplied reactor and outside box are not used?
Harmonics cannot be suppressed (controlled) correctly and noise cannot be removed. Be sure to connect the supplied reactor and outside box to the inverter. More Details >>
- No:21557
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
-
Inverter current characteristics
In general, relationship between T (torque), K (constant), V (voltage), I (current), and F (frequency) is expressed as "T = K × (V/F) × I". Since (V/F) is co... More Details >>
- No:21505
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
I cannot answer clearly because the load is unknown. The operation cycle of operating for 10 seconds and stopping for 10 seconds is OK, but it is questionabl... More Details >>
- No:21474
- Release Date:2018/08/22 16:27
- Category: FREQROL-E500
-
The reactor built in the FREQROL-A201 series is intended to stabilize operation of the converter circuit and differs from the FR-BAL. Note that when performi... More Details >>
- No:21421
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Options , Others
-
The stop-on-contact control does not function in the combined operation mode. Perform the control in the External operation mode. More Details >>
- No:21354
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Torque control cannot be performed with the FR-E700 series. It is available with the FR-A700 and FR-V500 series. More Details >>
- No:21279
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
SW1DND-FRC2 (FR Configurator2)
Yes. More Details >>
- No:21083
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
S45C (Carbon steel) is used. More Details >>
- No:21025
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
821-830 of Total 1353