FAQ within [ Drive Products ]
-
DC application method (Pr.162 = 0 or 10): 4 Hz or lower is regarded as 0 Hz. AC application method (Pr.162 = 3 or 13): It is not defined since it depends on ... More Details >>
- No:20905
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Output current: Because the filter, effective value of the output current displayed on the operation panel, is included, the momentary fluctuation is difficu... More Details >>
- No:20919
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
Replacement of the SF-JR with the SF-PR
Since the SF-PR is more efficient compared to the SF-JR, the resistance will decrease and the load current will increase. Check the following two points when... More Details >>
- No:20949
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Others
-
Sampling time of FR Configurator2
It depends on the mask count. It is approximately 0.125 [ms] (mask count: 1) to 20 [ms] (mask count: 30). More Details >>
- No:20950
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
Parameter copy to the USB memory
Yes. Parameters can be read except during an inverter reset or when the password function is set. More Details >>
- No:20961
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
The setting is enabled at the Y24 start-up. The frequency cannot be changed when Y24 is always ON. Turn ON Y24 when writing a frequency. More Details >>
- No:21048
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
A capacitive filter and common mode choke are built in. (A common mode choke is built in only for the 55K or lower.) Use a connector for whether to turn ON o... More Details >>
- No:21094
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , FREQROL-F800
-
Setting the tuning data without tuning makes no difference. The tuning method of the FR-A700 is different from that of V500. Tuning can be performed by setti... More Details >>
- No:21139
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Others , FREQROL-A700
-
The reactor generates a sound during power regeneration, but it is not abnormal. [Reason] The noise from the reactor is caused mainly by the magnetic attract... More Details >>
- No:21157
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Set Pr.55 (Frequency monitoring reference) of the first inverter to 70 Hz. More Details >>
- No:21257
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
841-850 of Total 1368