FAQ within [ Drive Products ]
-
If all inverters are in regenerative operation, the regenerative power is regenerated to the power supply. If one of the inverters is power driving, the rege... More Details >>
- No:21564
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
-
Faults history upon power failure
When an instantaneous power failure of 100 msec or longer occurs, the inverter is reset* and it is not recognized as a fault. Since it is not recognized as a... More Details >>
- No:21551
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
Current value on input side and output side
1. When slight imbalance (approximately 5%) is present with the inverter power supply voltage, the inverter input current can get imbalanced significantly. I... More Details >>
- No:21476
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-A200
-
You can use an inverter for fan and pump with the compressor, but it is not recommended for an application that the motor load rapidly increases. More Details >>
- No:21443
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A100
-
Using FR-A540 inverter on CC-Link
Answer to question 1 When the CC-Link option goes faulty, OPT (option error) occurs and the inverter's fault output is triggered. When communication is lost ... More Details >>
- No:21391
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500
-
The amount of heat generated by the FR-E500 series inverter is registered in the Mitsubishi Electric FA Global Website Member's page. Refer to the technical ... More Details >>
- No:21382
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E500
-
Countermeasure against the instantaneous power failure with the inverter
The power cannot be supplied to the control power supply separately for the FR-A024/A044 and small type FR-E500. Therefore, the UPS is not available. More Details >>
- No:21368
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A024 , FREQROL-E500
-
The copy function of the parameter unit (FR-PU04) is not available. Setting each parameter again or using the convert function of FR Configurator (FR-SW3-SET... More Details >>
- No:21337
- Release Date:2018/08/22 16:27
- Category: FREQROL-E700
-
The USB connection requires FR Configurator (FR-SW3-SETUP-WJ) prepared by Mitsubishi Electric Corporation. More Details >>
- No:21318
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Monitor code of CC-Link communication
The monitor with the code H01 switches by changing Pr.37 and Pr.144. More Details >>
- No:21236
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL