FAQ within [ Drive Products ]
-
Because when the FR-A8NC and FR-A8TR are used together, the wiring to the terminals becomes physically difficult. More Details >>
- No:20876
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
The error indicates that the parameter setting of the PLC function is not set. It is considered that the PC parameter is not checked when the PC parameter an... More Details >>
- No:20859
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800 , FREQROL-F800
-
Seamless communication of FR Configurator SW3
The communication via the MELSECNET is not available. More Details >>
- No:20830
- Release Date:2018/08/22 16:24
- Category: Engineering Software
-
SSCNET III/H during the power supply shut-off
In case that only main circuit power supply is cut off, communication remains. In case that the control circuit power supply of servo amplifier is cut off, t... More Details >>
- No:23646
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
Check if the communication setting parameters (Pr.117 to Pr.124) are set to the same values between the inverter and personal computer.Note that communicatio... More Details >>
- No:22105
- Release Date:2018/08/22 16:31
- Category: Inverters-FREQROL , FREQROL-A500
-
If the MC on the input side is shut off using the fault output of the FR-E500, the inverter's fault records are left in the faults history. More Details >>
- No:22096
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
The CAD data is found on the member's page of Mitsubishi Electric FA Global Website. More Details >>
- No:22091
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Others
-
Current value monitor indicator
The measurable frequency range and measurement precision of the inverter's output current greatly differ depending on the measurement instrument.Check with t... More Details >>
- No:22079
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Setting Pr.37 to the machine speed at 60 Hz switches the frequency monitor to the rotations per minute monitor.Note that the speed setting must be input in a... More Details >>
- No:22072
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Relationship between frequency and output torque
The output torque characteristics of the FREQROL-E500 series are shown in the figure below. Figure 1 More Details >>
- No:22024
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500