FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Torque control cannot be performed with the FR-E700 series. It is available with the FR-A700 and FR-V500 series. More Details >>
- No:21279
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700
-
Three phases are measured with the CT. The accuracy is ±10 % which is same as the inverter output current. More Details >>
- No:21145
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
The inverter may be broken due to the temperature rise of the internal parts. More Details >>
- No:21140
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Yes, it can. When the FR-A7NF is installed, the CS terminal is disabled. Assign the CS terminal function to other input terminals by setting the parameter. B... More Details >>
- No:21121
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Plug-in Options
-
A separate power supply is required according to the encoder power supply specification. More Details >>
- No:21090
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
The time from when the frequency command is applied until it is reflected on the operation of the motor is different. For the analog input, the multiple anal... More Details >>
- No:21050
- Release Date:2018/08/22 16:25
- Category: FREQROL-D700
-
When the winding ratio is large, the control according to the winding diameter is required. The upper controller has measured the winding diameter and create... More Details >>
- No:20974
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
No, it does not affect the control. When a swinging frequency is set in Pr.1074, the setting values in Pr.1077 to Pr.1079 are not referred. When Pr.1074 is s... More Details >>
- No:20952
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
Yes, because the same enclosure cut dimensions is adopted. More Details >>
- No:20866
- Release Date:2018/08/22 16:24
- Category: Options
-
The X114 signal is for switching the control to the dancer control or tension sensorless torque control. The signal input becomes invalid during operation be... More Details >>
- No:20845
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800