FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
When all of the multi-speed input signals are turned OFF during external operation, the output frequency conforms to the external analog frequency command (i... More Details >>
- No:22012
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
1. Can I set the frequency by the external potentiometer when multi-speed signal is 0 (nothing is input)?-> It is possible by using the external operation... More Details >>
- No:21990
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Use Pr.17 (Input terminal assignment) to assign MRS to the terminals DI1, DI2, and DI3. More Details >>
- No:21937
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-V200
-
No. the torque cannot be limited by using Pr.9.Set Pr.277 (Stall prevention current switching) to "1".The value of Pr.22 (Stall prevention operation level) w... More Details >>
- No:21766
- Release Date:2018/08/22 16:29
- Category: FREQROL-E700
-
Yes. More Details >>
- No:21749
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
The operation command source is automatically transferred to the connected FR-PU07 or FR-PA07. More Details >>
- No:21700
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-F700PJ
-
General-purpose magnetic flux control
Almost same control method. This control also performs vector calculation and divides the inverter's output current into an excitation current and into a tor... More Details >>
- No:21620
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
If the phase A and phase B are connected reversely, encoder feedback control is not performed. Instead, the inverter is operated in normal control (V/F contr... More Details >>
- No:21524
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500
-
The following are check points for abnormal conditions in addition to those given in the FR-Z200 manual. 1. Are the forward and reverse signals input simult... More Details >>
- No:21503
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-Z200
-
Inverter circuit breaker selection
Since the inverter leakage current is in proportion to the switching voltage of the transistor of the main circuit, the leakage current for the 400 V system ... More Details >>
- No:21429
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , Others , FREQROL-A500
881-890 of Total 1353