FAQ


FAQAbout Products

FAQ
Keyword Search
Drive Products
-
FREQROL-A800(144)
FREQROL-F800(89)
FREQROL-A700(352)
FREQROL-D700(261)
FREQROL-E700(394)
FREQROL-F700(296)
FREQROL-F700P(295)
FREQROL-F700PJ(252)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(123)
FREQROL-B(10)
FREQROL-E500(85)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(52)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(43)
Magnet motor drive(9)
Peripheral devices(7)
Options(129)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
The FM output is 0 to 8 VDC pulse. More Details >>
- No:22039
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
Fault contact when connecting separate power supply for each control circuit
Since the inverter's fault contact is an NC contact, it does not open unless a fault occurs.Therefore, when the control power supply (and main circuit power ... More Details >>
- No:22035
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Two-rank up maximum short-time torque
It is not possible to generate torque larger than the maximum possible torque of the motor by increasing the inverter's capacity.Even when the inverter is up... More Details >>
- No:22027
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
PHS does not cause the inverter to malfunction.On the contrary, if you use PHS near an inverter or motor, communication over PHS may become noisy or even get... More Details >>
- No:22018
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Change Pr.18 (High speed maximum frequency) to 400 Hz.If you are using the analog command to set the frequency, calibrate the 400 Hz frequency with Pr.903. More Details >>
- No:21931
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
When running the inverter in Advanced magnetic flux vector control, the frequency setting value is increased by the amount of the motor's slippage, resulting... More Details >>
- No:21801
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Check if any device is connected to the inverter's external terminal.In particular, check if MRS and SD are short-circuited.If they are short-circuited, open... More Details >>
- No:21753
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
The following is the amount of heat generated for each capacity:0.1K: 14W 0.2K: 20W 0.4K: 32W 0.75K: 50W1.5K: 80W 2.2K: 100W 3.7K: 160W 5.5K: 290W7.5K:... More Details >>
- No:21706
- Release Date:2018/08/22 16:29
- Category: FREQROL-E700
-
Yes. More Details >>
- No:21704
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , Others
-
Cycle operation mode, continuous operation mode, torque characteristic selection
When using a motor with an encoder by performing auto tuning, you need to choose the operation mode or continuous operation mode depending on the application... More Details >>
- No:21661
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
881-890 of Total 1368