It is available if the CC-Link option of the FR-A8NC is installed. More Details >>
- No:20894
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
It is 2 to 3 ms. By setting Pr.289 Inverter output terminal filter and Pr.699 Input terminal filter, the FR-A700 can be compatible with the response of the t... More Details >>
- No:20899
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Yes, they are. More Details >>
- No:20900
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Terminal 2 input selector switch when the PTC thermistor is connected
When the DIP switch is changed to I, it does not operate normally because the internal resistance changes. More Details >>
- No:20901
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL
-
Carrier frequency automatic reducing function
The function operates immediately when the current of 85% or higher flows. The limit is canceled when the current becomes 80% or lower. More Details >>
- No:20903
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Vector control: The SM1217 turns ON when the motor rotates even if no forward rotation command is send. Other than vector control: The SM1217 turn ON by forw... More Details >>
- No:20907
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Vector control cannot be selected unless Pr.862 is set to 1. (Only the first motor is supported in the motor setting of FR Configurator2.) More Details >>
- No:20908
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
Yes. More Details >>
- No:20910
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
Yes, the English version of SW3 is included. More Details >>
- No:20912
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
The English version of SW3 can be installed with the product ID of FR Configurator2 if it is Ver.5.50 or later. Since Ver.5.50 or former does not have a prod... More Details >>
- No:20913
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
81-90 of Total 1368