An earth plate permanently installed in the 700 series is included as an option for the 800 series because of the change of the shape of the circuit board. More Details >>
- No:21035
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
It depends on the scan time. More Details >>
- No:21042
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
Yes. However, it is difficult to wind the twisted wires because they are thick. More Details >>
- No:21128
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Three phases are measured with the CT. The accuracy is ±10 % which is same as the inverter output current. More Details >>
- No:21145
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
The acceleration time is 60 Hz and 5 seconds, and deceleration time is 60 Hz and 60 seconds. More Details >>
- No:21166
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
No. During JOG operation, deceleration stop is performed even though Pr.250 is set. More Details >>
- No:21199
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
It is fixed to 5 kHz. More Details >>
- No:21211
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
When the second torque limit is used, the settings of Pr.816 and 817 are valid. More Details >>
- No:21218
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
LED blinking under encoder feedback control
The Z-phase signal may be connected to the A-phase or B-phase incorrectly. Check the wiring. More Details >>
- No:21220
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
System environment variable of the Modbus-RTU communication
Other than "0" can be input. The inverter is reset by writing any numerical value. More Details >>
- No:21224
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL