FAQ


FAQAbout Products
FAQ
Keyword Search
Drive Products
-
FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
Harmonic suppression guidelines
A 200 V class inverter of 3.7 kW or smaller is the target of the harmonic suppression guidelines for household appliances and general-purpose products, and i... More Details >>
- No:21553
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
It is the brake function that consumes the rotational energy by heat and stops the motor immediately by short-circuiting between the motor terminals through ... More Details >>
- No:21066
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Others
-
The following reasons are possible. - The signal of Z phase does not exist. (It is not returned normally.) - The setting of Pr.359 encoder rotation direction... More Details >>
- No:21162
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700
-
The operation panel is also compatible with the IP55 More Details >>
- No:21091
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800
-
Yes. It can be carried out like under the dancer feedback speed control. More Details >>
- No:20885
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
Changing main speed at analog signal input
To change the running frequency while the frequency command is input to the terminal 2, adjust the parameters in the following steps:1. Change Pr.77 to "2".2... More Details >>
- No:22025
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
The inverter overcurrent shut-off fault indication E.OC1, E.OC2, or E.OC3 is not only displayed when the inverter output current reaches approximately 200% o... More Details >>
- No:21519
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A200
-
For the V/F control and Advanced magnetic flux vector control, the FR-A800 stops only by Pr.1103 Deceleration time at emergency stop. Pr.815 is not affected. More Details >>
- No:20860
- Release Date:2018/08/22 16:24
- Category: FREQROL-A800
-
The brake resistor is not built in the inverter. Purchase the optional resistor and connect it to the inverter.Inverter only (without resistor)Continuous reg... More Details >>
- No:21989
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
The ON level is the power supply voltage -3 V or higher and the OFF level is 3 V or lower. More Details >>
- No:21002
- Release Date:2018/08/22 16:25
- Category: FREQROL-A800 , Plug-in Options
81-90 of Total 1353