FAQ within [ Drive Products ]
-
For 200 V: The cover is attached for 15 K or lower. No cover is attached for 18.5 K or higher. For 400 V: The cover is attached for 55 K or lower. No cover i... More Details >>
- No:20988
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Yes. More Details >>
- No:20985
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Options
-
Vector control cannot be selected unless Pr.862 is set to 1. Only the first motor is supported in the motor setting of FR Configurator2. More Details >>
- No:20840
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Engineering Software , FREQROL-A800
-
For the 200 V type, the leakage current at the delta connection is 5 mA. For the 400 V type, it is 10 mA. More Details >>
- No:20835
- Release Date:2018/08/22 16:24
- Category: Options
-
1. As the reactor (FR-HCL) is connected when connecting the FR-HC, do not connect the FR-BAL. 2. The noise filter can be connected to the input side of the F... More Details >>
- No:22101
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
Pulse train output of terminal FM
Under Advanced magnetic flux vector control, the output frequency varies due to slip compensation. This may cause the output frequency monitor value to chang... More Details >>
- No:22054
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Notes when inverter capacity is larger than motor capacity
When using one-rank-higher inverter, as you mention, you need to care about the setting of the electronic thermal O/L relay.Setting the electronic thermal O/... More Details >>
- No:22040
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
The motor-generated torque elements have the following relationship:Torque T = K I V/FK: ConstantI: CurrentV: VoltageF: FrequencyThe inverter regularly perfo... More Details >>
- No:21952
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Operation of automatic restart after instantaneous power failure
1. No operation log is recorded.2. No. However, you can create a state indicating that automatic restart after instantaneous power failure is in progress by ... More Details >>
- No:21948
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Electronic thermal O/L relay setting
Set Pr.9 to the rated current at 50 Hz or a value 1.1 times as the rated current at 60 Hz.You can specify the motor type with Pr.71 (Applied motor). For a co... More Details >>
- No:21941
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL