FAQ within [ Drive Products ]
-
If Pr.361 = 0, the second terminal can be used as the line speed command when X114 is ON, and as the frequency setting value when X114 is OFF. If Pr.361 = 3,... More Details >>
- No:20891
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
When the value is written to Pr.646 (Stored winding diameter), the stored value is used. When the value is not written, the minimum or maximum winding diamet... More Details >>
- No:20887
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
The FR-E7TR does not have the terminal for the SC and it cannot be used with the FR-E700-SC. More Details >>
- No:20865
- Release Date:2018/08/22 16:24
- Category: FREQROL-E700
-
Yes, it does, however, it does not acquire the certification of the BACnet association standard. More Details >>
- No:20863
- Release Date:2018/08/22 16:24
- Category: FREQROL-F800
-
Perform the writing after turning ON the SOF, or after stopping the FR-HC2 by pressing the STOP button. Wire the RDY signal so that the inverter stops when t... More Details >>
- No:20842
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
It is possible when Pr.23 = 0 (Current limit at regenerative driving). More Details >>
- No:20826
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
The response delay time is 10 ms normally and 100 ms at startup. More Details >>
- No:20821
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Plug-in Options
-
The resistor unit MT-BR5 manufactured in February 2016 or later has output terminal TH3 (NC contact) as a fault output terminal. More Details >>
- No:20816
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Options
-
The following version or later is supported for Windows 8. MR Configurator2, 1.20W or later More Details >>
- No:23633
- Release Date:2018/09/14 15:10
- Category: Servo Support Software
-
Influence on external measurement device
It is considered that malfunction of the measurement device is due to noise. Check the noise propagation route since the countermeasure depends on it. Some c... More Details >>