FAQ within [ Drive Products ]
-
If the MC on the input side is shut off using the fault output of the FR-E500, the inverter's fault records are left in the faults history. More Details >>
- No:22096
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500
-
With the FREQROL-U100 series, pressing and holding the [SET] switches to the current monitor. More Details >>
- No:22073
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-U100
-
Fault output terminal load pattern
The fault output terminals A and C, and B and C of the power regeneration converter FR-RC are not capable of a micro load of 5 VDC±5%, 10 mA. The minimum loa... More Details >>
- No:21966
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
Electronic thermal O/L relay setting
Set Pr.9 to the rated current at 50 Hz or a value 1.1 times as the rated current at 60 Hz.You can specify the motor type with Pr.71 (Applied motor). For a co... More Details >>
- No:21941
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
When running the inverter in Advanced magnetic flux vector control, the frequency setting value is increased by the amount of the motor's slippage, resulting... More Details >>
- No:21801
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Advanced magnetic flux vector control
When using the geared motor GM-S(B), set Pr.71 to "13" and also set Pr.9, Pr.80, and Pr.81.Perform auto tuning as required. Perform auto tuning as required. ... More Details >>
- No:21756
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
1:1500 when using a vector control dedicated motor. Continuous 100% torque operation and short-time 150% torque operation are possible even at 1 rpm. Continu... More Details >>
- No:21662
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-V200
-
Comparison of noise between FR-A100 and FR-A100E
The setting ranges of the carrier frequency are:- FR-A100: 2 kHz to 14.5 kHz- FR-A100EXCELLENT: 0.7 kHz to 14.5 kHzThe range of the FR-A100EXCELLENT is exten... More Details >>
- No:21623
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A100
-
Difference from conventional product (parameter unit)
The parameter unit is not available. Use two internal potentiometers to set the electronic thermal O/L relay and acceleration/deceleration time, and two swit... More Details >>
- No:21585
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , SC-A
-
The internal processing speed is not published. The analog input specifications are as follows: FR-A500???1/4000FR-E500???1/1000MR-H???1/4000 More Details >>
- No:21550
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-E500