FAQ within [ Drive Products ]
-
No. The "RUN" key on the FR-PA07 does not work.The start command is accepted from the external source. More Details >>
- No:21703
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-F700PJ
-
The FR-E720S series and D720S series conform to the single-phase 200 V input specifications. More Details >>
- No:21723
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700
-
If you are using CC-Link just to monitor the inverter and using the analog signal and multi-speed setting to set the frequency, you need to input them extern... More Details >>
- No:21900
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
Can I use a brake resistor with the FR-S500?
The brake unit and its resistor FR-S520-0.4K to 3.7K are available.Mitsubishi Electric FA Global Website also explains so.(Note that the GZG GRZG discharging... More Details >>
- No:21970
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-S500
-
If multiple line noise filters are wound without clearance between them, the noise reduction effect corresponding to the number of filters cannot be obtained... More Details >>
- No:22087
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , Options
-
Setting values of the FR-F800 when replaced with the FR-F400
The performance and noise countermeasure were improved and the initial value is set to "8". Try with the initial value "2" first. If the noise is distracting... More Details >>
- No:20808
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
When only the main circuit input power supply is cut off with the MC (when the power supply shutoff time is long), the main circuit undervoltage or instantan... More Details >>
- No:20833
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800 , FREQROL-F800
-
Power supply harmonics countermeasure
Use a high power factor converter FR-HC2 or reactor as needed. More Details >>
- No:21115
- Release Date:2018/08/22 16:26
- Category: FREQROL-A800 , FREQROL-F800
-
With the automatic bypass sequence (Pr.139 ≠ 9999, Pr.159 = 9999), the motor operation is switched to commercial power supply operation when the output frequ... More Details >>
- No:21189
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P
-
Advanced magnetic flux vector control
Set "13" in Pr.71. Always perform auto tuning. More Details >>
- No:21299
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-E700