FAQ within [ Drive Products ]
-
From before, the QCPU has been used and each setting does not make a difference internally. Thus, the selection was reduced to the QCPU only. It can also be ... More Details >>
- No:20868
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Engineering Software
-
When the winding ratio is large, the control according to the winding diameter is required. The upper controller has measured the winding diameter and create... More Details >>
- No:20974
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-A800
-
Pr.59 is available in the products manufactured in October 1995 or later. Therefore, it cannot be read from the products manufactured before October 1995. More Details >>
- No:21170
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , FREQROL-A024
-
No load current value of motor
No load current for each power supply voltage is as follows:- Approximately 15.5 A for 200 VAC 60 Hz- Approximately 21.7 A for 220 VAC 60 HzThe current is es... More Details >>
- No:21534
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Others
-
How can I have the motor coast to stop?
You can use the following two methods:1. Turn ON MRS at the same time when STF turns OFF.2. Set Pr.10 = 60 Hz, Pr.11 = 0 sec, and Pr.12 = 0% (when the invert... More Details >>
- No:21967
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
By either of following methods: (MR-J4) 1. On MR Configurator2, select [Diagnosis] - [Alarm Display] - [Clear]. 2. Set alarm history clear of parameter to "... More Details >>
- No:23650
- Release Date:2018/09/14 15:10
- Category: MELSERVO-J4
-
For the Instruction Manual "Applied", fill in the request sheet which is included in the last part of the Instruction Manual "Basic", and fax it to the speci... More Details >>
- No:21341
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
You cannot remove the key sheet from products with the key sheet attached as a standard other than the PU operation type. When using the parameter unit FR-PU... More Details >>
- No:21596
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-U100
-
Switching between external operation and NET operation
You can switch between external operation and NET operation by turning ON/OFF the terminal X66 (RM). You can switch while Pr.79 (Operation mode) is set to "6... More Details >>
- No:21688
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Rapid blinking of the RUN LED indicates that the frequency setting command has not been input or the output stop signal has been input.Since Pr.79 is set to ... More Details >>
- No:21853
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ