Calculation of acceleration/deceleration time
As the inverter, you can basically use the equation below to calculate the acceleration/deceleration time.Note that you should consider a factor of 120% for ... More Details >>
- No:21965
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
Before you change Pr.7 and Pr.8, you must switch to the PU operation mode. Switch to the PU operation mode and change them. More Details >>
- No:21984
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-F500
-
MR Configurator2 has been improved in the following. ・The servo assistant function introduces the related functions for each operation step to enable the f... More Details >>
- No:23658
- Release Date:2018/09/14 15:10
- Category: Servo Support Software
-
A current fluctuation may result in abnormal noise from the peripheral device or the flickering fluorescent light. More Details >>
- No:21155
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Options
-
Watt-hour meter clear and operation hour meter clear
The values are set to Pr.170 and 171 when the monitor value of cumulative power and actual operation time overflows. It does not affect the operation. Use it... More Details >>
- No:21197
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Vector control cannot be selected unless Pr.862 is set to 1. Only the first motor is supported in the motor setting of FR Configurator2. More Details >>
- No:20840
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , Engineering Software , FREQROL-A800
-
The English version of SW3 can be installed with the product ID of FR Configurator2 if it is Ver.5.50 or later. Since Ver.5.50 or former does not have a prod... More Details >>
- No:20913
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Engineering Software
-
It is not completely recommended to use F700P because the starting torque at low speed of the hydraulic pump may be larger than that of the normal pump. Sele... More Details >>
- No:21126
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL , Others
-
Connecting voltmeter to terminal AM
You can connect them in parallel. Connect the voltmeters in parallel, paying attention to the following: - The output current should not exceed the permissib... More Details >>
- No:21464
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL
-
Regenerative driving capability
Continuous 100% regenerative braking torque is available for the rated capacity of the high power factor converter. (The same braking ability of the FR-A201 ... More Details >>
- No:21563
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Options
971-980 of Total 1353