It is available if the CC-Link option of the FR-A8NC is installed. More Details >>
- No:20894
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
It is possible when the dancer control and tension sensor feedback speed control is used and the PID calculation is turned OFF. Because the PID compensation ... More Details >>
- No:20889
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
It indicate that the actual number of connectable units differs depending on the master side specification although the maximum number of connectable units o... More Details >>
- No:20839
- Release Date:2018/08/22 16:24
- Category: Inverters-FREQROL , FREQROL-A800
-
Imbalanced input side power supply
1. Power supply voltage phase imbalance toleranceMitsubishi inverter's input power supply voltage phase imbalance tolerance is ±3%.If the phase imbalance exc... More Details >>
- No:21987
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
We do not provide such plug-in optional cards. More Details >>
- No:21981
- Release Date:2018/08/22 16:30
- Category: Magnet motor drive
-
Speed 2 operation with potentiometer on operation panel
Yes. Set parameters as below.For FR-E500Set Pr.79 =3, and Pr.146= 0.Multi-speed is prioritized.For FR-S500Set Pr.79 = 3, and Pr.53 = 1.Multi-speed is priorit... More Details >>
- No:21963
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-E500 , FREQROL-S500
-
Short-circuiting frequency setting terminals
You can short-circuit the terminals 10 and 2.If you are considering to perform operation at the maximum frequency, consider using the high-speed command RH o... More Details >>
- No:21951
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
I want to display the speed on an analog meter.
As the inverter does not display the speed in m/min, let us explain using the speed display in r/min. In this case, set Pr.52 to "6" (operation panel display... More Details >>
- No:21944
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
The FR-E720S series and D720S series conform to the single-phase 200 V input specifications. More Details >>
- No:21723
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700
-
Compatibility of plug-in option
Use the plug-in option dedicated for the FR-A100EXCELLENT. To avoid an incorrect installation, the connector position for the plug-in option and the FR-A100E... More Details >>
- No:21632
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , Plug-in Options , FREQROL-A100