FREQROL-A800(142)
FREQROL-F800(89)
FREQROL-A700(351)
FREQROL-D700(260)
FREQROL-E700(393)
FREQROL-F700(295)
FREQROL-F700P(294)
FREQROL-F700PJ(251)
FREQROL-A024(40)
FREQROL-A100(21)
FREQROL-A200(32)
FREQROL-A500(119)
FREQROL-B(9)
FREQROL-E500(84)
FREQROL-F400(2)
FREQROL-F500(15)
FREQROL-S500(11)
FREQROL-U100(16)
FREQROL-V200(51)
FREQROL-Z020(1)
FREQROL-Z024(2)
FREQROL-Z100(2)
FREQROL-Z123(2)
FREQROL-Z200(3)
FREQROL-Z300(2)
SC-A(12)
Engineering Software(41)
Magnet motor drive(9)
Peripheral devices(7)
Options(127)
Plug-in Options(30)
Others(53)
FAQ within [ Drive Products ]
-
A motor overheats (the current increases) when the load is heavy.When the electronic thermal O/L relay works, you need to mitigate the load.If the current is... More Details >>
- No:22042
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Current value monitor indicator
The measurable frequency range and measurement precision of the inverter's output current greatly differ depending on the measurement instrument.Check with t... More Details >>
- No:22079
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
Yes, the circuit board coating and conductive plating are applied to the HC2 as standard. More Details >>
- No:21026
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
When the second torque limit is used, the settings of Pr.816 and 817 are valid. More Details >>
- No:21218
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
Using a general-purpose inverter to drive a three-phase induction motor can save energy under the following two types of loads (application): 1. Constant-t... More Details >>
- No:21537
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL
-
1. Select the circuit breaker and MC in accordance with the inverter type.2. Select the power factor improving reactor in accordance with the motor output. More Details >>
- No:21946
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL
-
EEPROM writing with the communication option
The writing from the parameter unit or operation panel is always ROM write regardless of the setting value of Pr.342. More Details >>
- No:21206
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
The count is resumed from 0. Thus, the times of the overflow is reset. More Details >>
- No:20902
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL
-
The initial value of Pr.78 (Reverse rotation prevention selection) of the MD-CX522 is "1" (reverse rotation is disabled). When performing forward rotation an... More Details >>
- No:21168
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL
-
The noise amount does not change because the carrier frequency does not change. More Details >>
- No:21198
- Release Date:2018/08/22 16:26
- Category: Inverters-FREQROL