FAQ
FAQAbout Products
- FAQ > Controllers > Motion Controllers
FAQ
Keyword Search
Motion Controllers
FAQ within [ Motion Controllers ]
-
Because the rapid stop deceleration time is larger than the deceleration time.Set the rapid stop deceleration time within the range of 1 to the deceleration ... More Details >>
- No:23551
- Release Date:2018/09/14 15:09
- Category: RnMTCPU
-
Error 1205 (SSCNET communication error) occurs when erroneous data is received from servo amplifier. [When the servo parameter "[PA14] Rotation direction se... More Details >>
-
Warning 093CH (Home position return data incorrect) occurs when the backup data for absolute position restoration is lost.Execute the machine home position r... More Details >>
-
CUP type of stand-alone Motion controller
The following shows the specification for the PLC CPU area. Q170MSCPU: Equivalent to PLC CPU "Q03UDCPU" • Program capacity: 30k steps • LD instruction proces... More Details >>
-
Error 2035 (Command frequency error) occurs when the servo amplifier detects a command frequency error. (1) When the command is the permissible speed or high... More Details >>
-
Acceleration/deceleration time change
Yes, the time can be changed during operation by using the acceleration/deceleration time change function. Set the acceleration/deceleration time change para... More Details >>
- No:23569
- Release Date:2018/09/14 15:09
- Category: RnMTCPU
-
MELSOFT MT Works2 is engineering software for Motion controllers that provides comprehensive support - from system design, parameter settings, program creati... More Details >>
- No:23565
- Release Date:2018/09/14 15:09
- Category: MELSOFT MT Works2
-
Set "[Cd.6] Restart command" to "1". More Details >>
-
Set "[Pr.45] Home position address" of the basic parameters for home position return • Axis 1 to 16: 72+150n, 73+150n • Axis 17 to 32: 1000072+150n, 1000073+... More Details >>
-
Refer to "b2: Command in-position flag" of "[Md.31] Status". More Details >>
41-50 of Total 72