FAQ


FAQAbout Products

FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
How to increase file register capacity
An SRAM card can increase file register capacity.1MB/2MB/4MB/8MB SRAM cards are available.The numbers of file registers that can be used with a 1MB, 2MB, 4MB... More Details >>
- No:22687
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
GX Works3 is compatible with the following OSs. (As of Sep,2018) - Microsoft Windows 10 - Microsoft Windows 8.1 - Microsoft Windows 8 - Microsoft Windo... More Details >>
- No:22473
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:38
- Category: MELSEC iQ-R Series
-
How to increase file register capacity
In LCPU, file register capacity depends on CPU. The number of file register points cannot be increased. (A file register cannot be set on an SD memory card.)... More Details >>
- No:22766
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
A password can be set. - Use the file password 32 function.- Number of characters: 4 to 32 (alphanumeric and special characters, case-sensitive)- Disabled op... More Details >>
- No:22810
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
T-branch connection and star topology for CC-Link networks
- T-branch T-branch is a connection type that branches one line from a main line. To establish a T-branch CC-Link network, use the repeater module AJ65S... More Details >>
- No:23024
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:00
- Category: Network related products
-
Regarding iQ-F Series Project Conversion
It's possible. In GX Works3, select [Project] → [Change Module Type/Operation Mode], and select the Series: MX controller, Type/Model: MXF100, Number of Axes... More Details >>
- No:44987
- Release Date:2025/05/08 09:09
- Category: MELSEC MX Controller MX-F Model
-
Alarm E7 (Controller forced stop warning) occurs when an forced stop is executed by the Positioning module or the Simple Motion module. The following shows h... More Details >>
-
Error 108 (Start not possible) occurs when a start is requested while a stop signal is ON.Check the "[Md.26] Axis operation status".If "20: Servo amplifier ... More Details >>
-
No. The motors' operation is not completely linked to ON/OFF timing of the BUSY signals.BUSY signal is turned ON when the controller starts sending commands ... More Details >>
-
The torque limit value can be changed regardless of JOG operation status.Set the new torque limit value with "[Cd.22] New torque value/forward new torque val... More Details >>
1-10 of Total 1110