The error code "2110" is "SP.UNIT ERROR.". This error may be caused by one of the following factors. (1) The module that has been specified by a FROM/TO i... More Details >>
- No:22662
- Release Date:2018/09/03 17:29
- Update:2018/09/21 13:48
- Category: MELSEC-Q Series
-
Communications using the built-in USB port of the FX3 series
When you connect the built-in USB port of the FX3 series to the personal computer for the first time, you need to install the USB driver into the personal co... More Details >>
- No:22273
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Engineering Software , Main Unit , Network/Communication
-
The following shows the devices for the battery errors. • [SM51] Battery low latch Turn ON when the voltage of battery reduces to less than 2.5[V]. Remains O... More Details >>
-
The error code "2100" is "SP.UNIT LAY ERR.". This error may be caused by one of the following factors. (1) In the I/O assignment setting of the PLC parame... More Details >>
- No:22650
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:47
- Category: MELSEC-Q Series
-
The error code "2100" is "SP.UNIT LAY ERR.". This error may be caused by one of the following factors. (1) An intelligent function module is assigned as a... More Details >>
- No:22725
- Release Date:2018/09/03 17:29
- Update:2018/09/21 17:02
- Category: MELSEC-L Series
-
Grounding FG and LG terminals of power supply module
Both of them need to be grounded. They can be shorted and grounded as one cable. More Details >>
- No:22527
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
The error code "2401" is "FILE SET ERROR". The individual information parameter number "1100H" corresponds to a file register. The cause of the error is th... More Details >>
- No:22535
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:46
- Category: MELSEC-Q Series
-
GX Works3 is compatible with the following OSs. (As of Sep,2018) - Microsoft Windows 10 - Microsoft Windows 8.1 - Microsoft Windows 8 - Microsoft Windo... More Details >>
- No:22473
- Release Date:2018/09/03 17:28
- Update:2018/09/21 16:38
- Category: MELSEC iQ-R Series
-
When the message "An unusable COM port was specified" is displayed
RS-232 is selected as PC side I/F in Transfer Setup of GX Developer or GX Works2.Change the setting in PC side I/F to USB. More Details >>
- No:22517
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
M8029 (Instruction execution complete flag) is shared with multiple instructions. To obtain an execution completion result of a specific instruction, insert... More Details >>
- No:24775
- Release Date:2019/02/27 15:34
- Category: MELSEC-F Series , Network related products , Main Unit