FAQ within [ MELSEC iQ-F Series ]
-
Reagrding specifying an FTP client domain
The iQ-F series does not support domain specification, so specify the IP address. More Details >>
- No:44359
- Release Date:2024/03/27 15:58
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding multiple connections for the MQTT communication function
The MQTT communication function of FX5-ENET does not allow multiple connections to be opened at the same time. The MQTT communication function has a maximum ... More Details >>
- No:44358
- Release Date:2024/03/27 16:02
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding dedicated instruction for JOG operation
There is no dedicated instruction to drive JOG. Use PLSV (variable speed operation) when operating JOG. More Details >>
- No:44355
- Release Date:2024/03/27 15:50
- Category: MELSEC iQ-F Series , CPU Module , Motion/Positioning
-
Regarding Circuit Blocks that cannot be written with Online Program Change.
HIOEN/DHIOEN instructions cannot be written with Online Program Change. In addition, circuit blocks containing positioning instructions or network instructio... More Details >>
- No:44354
- Release Date:2024/03/27 15:47
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding Bus Conversion Module Differences
The FX5-CNV-BUS is an additional cable type. ・Used when the FX5-CNV-BUS previous module is an expansion cable type module. The FX5-CNV-BUSC is an a... More Details >>
- No:44353
- Release Date:2024/03/27 15:49
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding connector conversion module differences
The FX5-CNV-IF is an additional cable type. ・FX5U/FX5UJ CPU Modules are supported. ・Used to connect an extension connector type module to an extension ca... More Details >>
- No:44351
- Release Date:2024/03/27 15:45
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding program conversion from FX3 Series to iQ-F Series
You can convert an FX3 series project (extension.gxw) to an iQ-F series project by selecting and opening it from the GX Works3 Projects > Open Other Forma... More Details >>
- No:44349
- Release Date:2024/03/27 15:31
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding differences between Analog Module and Analog Adapters
FX5-4AD and FX5-4DA are intelligent function Modules. ・Connect to the right side of the CPU Module. ・Control via buffer memory (BFM). ・It also supports ... More Details >>
- No:44347
- Release Date:2024/03/27 15:21
- Category: MELSEC iQ-F Series , Analog
-
Regarding issuing Client Certificates to Connect with AWS IoT Core
Set the RSA strength to at least 2048 bits. Anything less than 2048 bits is not supported by AWS IoT Core and cannot be connected. More Details >>
- No:44343
- Release Date:2024/03/20 13:34
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding write speed during RUN
CC-Link IE field Network Basic communication interval can be set with special relay and special register. During debugging, adjust the communication interv... More Details >>
- No:44342
- Release Date:2024/03/20 13:39
- Category: MELSEC iQ-F Series , CPU Module