FAQ


FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series
FAQ
Keyword Search
FAQ within [ MELSEC iQ-F Series ]
-
Regarding how to format an SD memory card
In GX Works3, go to Online > CPU Memory Operation, select "SD Memory Card" and execute "Initialization." More Details >>
- No:39344
- Release Date:2023/02/15 10:03
- Category: MELSEC iQ-F Series , Option , CPU Module , Engineering Software
-
Regarding registering profiles
Launch GX Works3, select a profile and register it from Tools > Profile Management > Register. More Details >>
- No:44360
- Release Date:2024/03/27 16:01
- Category: MELSEC iQ-F Series , Engineering Software
-
Regarding the link refresh settings of FX5-CCL-MS
It is possible to use latch devices or I/O devices (X/Y) for link refresh devices. However, when using I/O devices (X/Y), use I/O numbers (such as X1000 ~/Y... More Details >>
- No:22308
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:37
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
Regarding EtherCAT Communications
The FX5 CPU module does not support EtherCAT communication. There are no products in the FX series or iQ-F series that support EtherCAT communication. More Details >>
- No:39313
- Release Date:2023/02/14 08:54
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding how to Monitor Buffer Memory Values
You can monitor buffer memory values in the Ladder Editor by setting in GX Works3 >Tools >Options > Monitor > Common Item > Monitor Buffer Mem... More Details >>
- No:39324
- Release Date:2023/01/12 16:56
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding how to clear simple CPU communication function errors
After removing the error factor, you can clear it by executing "Clear latest error code" from "Diagnostic" - "Simple CPU Communication Diagnostic" in GX Work... More Details >>
- No:40049
- Release Date:2023/08/25 09:06
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding I/O assignment on the module configuration diagram of GX Works3
While the module configuration window is being displayed, the I/O assignment can be checked by selecting the following options from the menu bar: [Edit]→[X... More Details >>
- No:22307
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:25
- Category: CPU Module , I/O Module , Engineering Software
-
Regarding CC-Link settings using GX Works3
Parameters can be set when connecting the MELSEC iQ-F series with FX5-CCL-MS(CC-Link system master/intelligent device). However, when connecting with FX3U-1... More Details >>
- No:22317
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:19
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
-
Regarding How to release Online Program Change
In GX Works3, [Tools] - [Options] - [Conversion] - [Online Program Change], set "Execute Online Program Change in Converting" to "No." More Details >>
- No:44876
- Release Date:2025/03/18 10:26
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the method to connect with multiple devices via Ethernet port
Multiple connections can be established by using a switching hub. More Details >>
- No:22321
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:26
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software , Network/Communication
11-20 of Total 253