Regarding the maximum number of connections for MODBUS communication
32 stations can be connected when RS-485 port is used and only 1 station can be connected when RS-232 port is used. More Details >>
- No:22324
- Release Date:2018/08/30 13:55
- Update:2023/06/23 10:49
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding the Connected/Disconnected Module Detection button on FX5-CCLGN-MS
For the Connected/Disconnected Module Detection of FX5-CCLGN-MS, the network configuration of the subsequent stages can not be automatically detected unless ... More Details >>
- No:39274
- Release Date:2023/01/12 16:45
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding Open/Close Socket Communications
No need. More Details >>
- No:39288
- Release Date:2023/02/13 15:36
- Category: MELSEC iQ-F Series , CPU Module , Network/Communication
-
Regarding bit specification index modification for word devices
Index modification cannot be done for bit specifications for Word device. More Details >>
- No:39299
- Release Date:2023/02/13 16:39
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding firmware updates for newly purchased CPU modules
You can still update the firmware. More Details >>
- No:39300
- Release Date:2023/02/13 16:40
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding the driving contacts of high-speed counter instructions
The current value of the high-speed counter is retained and will not be cleared. More Details >>
- No:39304
- Release Date:2023/02/13 16:40
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
Regarding the effect of battery voltage drop on logging function
Since the battery retains clock data even after power failure, the time of logging data may change. More Details >>
- No:39310
- Release Date:2023/01/12 16:53
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding converting FBD/LD Projects
It can't be converted. More Details >>
- No:39328
- Release Date:2023/02/14 09:05
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding the procedure for functions set in GX Works3
This is possible with the Guidance flow function. On GX Works3, you can view the setting procedure for the function you want to use. *It is supported by GX ... More Details >>
- No:39341
- Release Date:2023/02/14 17:29
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Regarding clearing the maximum and minimum scan times
It can be cleared with the scan time clear function. You can clear maximum and minimum scan time with GX Works3 Ver. 1.085 P or later or by special relays. More Details >>
- No:39342
- Release Date:2023/02/15 10:05
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software