FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC > MELSEC iQ-F Series > CPU Module
FAQ
Keyword Search
FAQ within [ CPU Module ]
-
Regarding how to clear simple CPU communication function errors
After removing the error factor, you can clear it by executing "Clear latest error code" from "Diagnostic" - "Simple CPU Communication Diagnostic" in GX Work... More Details >>
- No:40049
- Release Date:2023/08/25 09:06
-
Regarding CC-Link IE Filed Basic Protocol Mixing
It is possible to mix CC-Link IE Filed Basic and general-purpose Ethernet communication. More Details >>
- No:40031
- Release Date:2023/08/24 14:40
-
Regarding Data Collection for Device Comments
It is not possible to collect device comments. More Details >>
- No:40030
- Release Date:2023/08/24 14:40
-
Regarding MODBUS Device Allocation Settings
No need. The MODBUS device allocation settings are used when the MODBUS slave function is used. More Details >>
- No:40026
- Release Date:2023/08/24 14:37
-
Regarding Instruction description help in GX Works3
You can open the descriptions for each instruction by moving the cursor to the target instruction and pressing F1. You can also hover the cursor over it and ... More Details >>
- No:39366
- Release Date:2023/02/15 13:06
-
Regarding the difference of current address (user unit, pulse unit)
The difference between the current address (user unit) and the current address (pulse unit) is as follows: The current address (user unit) becomes the unit ... More Details >>
- No:39357
- Release Date:2023/02/15 13:05
-
Regarding changing the current address (user unit, pulse unit)
It can be changed. It is now possible to write to the address (user unit, pulse unit) by the DHCMOV command. However, writing is disabled during positioning... More Details >>
- No:39356
- Release Date:2023/02/15 13:03
-
Regarding reading Sample Comments for Expansion Adapters
You cannot. The expansion adapters does not support reading sample comments. More Details >>
- No:39352
- Release Date:2023/02/15 10:16
-
Regarding the differences between Latches (1) and (2)
Whether or not the latch range is set by default and the range to "clear values" from CPU memory operations are different. You can clear with two options: c... More Details >>
- No:39351
- Release Date:2023/02/15 13:08
-
It cannot. Because there will be two CC-link IE field network Basic master stations in a network. More Details >>
- No:39346
- Release Date:2023/02/15 10:05
- Update:2024/04/25 10:10
71-80 of Total 158