Regarding the cause of communication error with GX Works3
From the PC's Internet Protocol Version 4 Properties, uncheck "Obtain an IP address automatically" option and set an arbitrary IP adress that does not dupli... More Details >>
- No:22319
- Release Date:2018/08/30 13:55
- Update:2023/02/13 11:38
- Category: MELSEC iQ-F Series , CPU Module , Engineering Software
-
Interrupt program priority setting of MELSEC iQ-R series
You can set interrupt priorities 5 to 7 for interrupt pointers (I0 to I15, I50 to I1023) from the module. You cannot change the priorities of interrupt poin... More Details >>
- No:22482
- Release Date:2018/09/03 17:28
- Update:2018/09/19 16:05
- Category: MELSEC iQ-R Series
-
How to install a USB driver in Windows XP
For how to install a USB driver in Windows XP, refer to the following procedure. (1) Connect a personal computer and a programmable controller CPU with a ... More Details >>
- No:22933
- Release Date:2018/09/03 17:30
- Update:2018/09/22 16:59
- Category: Engineering Software
-
Set "[Cd.16] Inching movement amount", and turn ON the Forward run JOG start signal or the Reverse run JOG start signal. More Details >>
-
There are two ways to start a positioning operation: (1) Set the "[Cd.3] Positioning start No.", and turn ON the positioning start signal. (2) Use the dedica... More Details >>
-
How to install a battery to FX3G/FX3GC series
The FX3U-32BL can be installed to the FX3G/FX3GC series. After installation, select [Battery Mode: Use the battery] on the FX parameter window of GX Develop... More Details >>
- No:22271
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , Accessories
-
Models of batteries that can be used with MELSEC iQ-R series CPU modules
You can use "Q6BAT" and "Q7BAT". You cannot use "Q8BAT". More Details >>
- No:22469
- Release Date:2018/09/03 17:28
- Category: MELSEC iQ-R Series
-
Unable to select [Transfer Setup]
If a circuit is being monitored or a monitor window such as the device batch monitor window is open, [Transfer Setup] on the menu is grayed out. Select [Wi... More Details >>
- No:22548
- Release Date:2018/09/03 17:28
- Update:2018/09/20 15:40
- Category: MELSEC-Q Series
-
Set "[Pr.45] Home position address (72+150n, 73+150n)" of the basic parameters for home position return.Set by 2 words.The value will be reflected when PLC r... More Details >>
-
Number of FX3U-1PG pulse output blocks that can be connected to the FX3U/FX3UC main unit
For the FX3U series, up to eight FX3U-1PGs can be connected. For the FX3UC series, up to six FX3U-1PGs can be connected. * To connect the FX3U-1PG to the... More Details >>
- No:24973
- Release Date:2019/04/23 07:19
- Category: MELSEC-F Series , Positioning Control