FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
Regarding Cloud recommended Services
AWS IoT Core and Azure IoT Hub are recommended. *AWS IoTCore is a registered trademark of Amazon Web Services, Inc. *Azure IoT Hub is a registered ... More Details >>
- No:40036
- Release Date:2023/08/24 15:42
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding connecting to AWS IoT Core Using the TCP Protocol
Because the AWS IoT Core specification is the TLS protocol, you cannot connect using the TCP protocol. More Details >>
- No:44344
- Release Date:2024/03/20 13:37
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the data link program of FX5-CCL-MS
Since the FX5-CCL-MS has a link refresh setting, there is no need for a program to read and write data to each station. More Details >>
- No:44614
- Release Date:2024/11/28 16:12
- Category: MELSEC iQ-F Series , Network/Communication
-
How to ground programmable controllers
For your safety, programmable controllers must be grounded. Incomplete common grounding within the control panel or common grounding with heavy electrical s... More Details >>
- No:22276
- Release Date:2018/08/30 13:48
- Category: MELSEC-F Series , Main Unit , I/O Extension
-
Regarding the maximum number of channels of high-speed counters
The FX5 CPU module's built-in high-speed counter can control up to 8CH. Up to 16CH can be controlled by adding 4 modules of FX5-16ET/E□-H (high-speed pulse ... More Details >>
- No:22311
- Release Date:2018/08/30 13:55
- Update:2023/02/13 15:34
- Category: MELSEC iQ-F Series , CPU Module , High-Speed Counter
-
GX Configurator-MB for the MODBUS(R) interface module
GX Configurator-MB does not need to be purchased. Parameters can be set using GX Works2 alone. More Details >>
- No:22701
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
FNC connector pin layout in L series I/O module and Q series I/O module
Yes. They have the same pin layout. More Details >>
- No:22774
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Simultaneous use of auto logging and backup functions
The auto logging function and backup function cannot be used simultaneously. The backup function must be used after the logging function is stopped. (A singl... More Details >>
- No:22819
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Opening SFC programs in GX Works2
To open a GX Developer project, select [Project] -> [Open Other Data] -> [Open Other Project] from the menu of GX Works2. More Details >>
- No:22878
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Necessity of terminating resistors in CC-Link communication
No, it is unnecessary. Terminating resistors are only required at both ends of the network. More Details >>
- No:22966
- Release Date:2018/09/03 17:31
- Category: Network related products
591-600 of Total 1123