FAQ


FAQAbout Products
FAQ
Keyword Search
Controllers
FAQ within [ Controllers ]
-
CPU operation when the time setting failed
When an error occurs, the operation can be stopped or continued according to the "At Error Occurrence" setting.(The default is "Continue".) More Details >>
- No:22828
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Editable range of Inline Structured Texts
Up to 2048 characters can be entered in the inline Structured Text box. The limit cannot be increased. Note that a line break is counted as 2 characters. More Details >>
- No:22852
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
Adding statements to SFC programs
No statements can be added. Please add notes or comments instead. More Details >>
- No:22896
- Release Date:2018/09/03 17:30
- Category: Engineering Software
-
RS-485 connection between QJ71C24N and an external device
Short between SDA and RDA and between SDB and RDB, and then connect them to + (Data-A) and - (Data-B) on the external device. More Details >>
- No:22986
- Release Date:2018/09/03 17:31
- Category: Network related products
-
For CPU modules with 8192 I/O device points (X/Y0 to 1FFF), X/Y1000 and greater can be set as refresh devices. More Details >>
- No:23014
- Release Date:2018/09/03 17:31
- Category: Network related products
-
CC-Link IE Controller cable standard
Use the cables that meet the IEC60793-2-10 Types A1a.1 optical fiber standard. The connectors are LC (duplex) connectors. Two cores are required.The core di... More Details >>
- No:23032
- Release Date:2018/09/03 17:31
- Update:2018/09/27 12:14
- Category: Network related products
-
Receiving data when no receive complete code is designated (QJ71C24N)
Data are received on a received data count basis. If there is no receive complete code and variable length data is received, the data is received at every no... More Details >>
- No:23038
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Continuous executions of protocols by the QJ71C24N series CPRTCL instruction
One CPRTCL instruction can execute a maximum of eight protocols. More Details >>
- No:23050
- Release Date:2018/09/03 17:31
- Category: Network related products
-
SB/SW refresh device setting with CC-Link
There are no problems even though the SB/SW refresh device has not been set. More Details >>
- No:23080
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Number of FX3U-ENET-L Ethernet interface blocks that can be connected to the FX3U series
One FX3U-ENET-L can be connected. More Details >>
- No:24939
- Release Date:2019/04/18 14:24
- Category: MELSEC-F Series , Network/Communication
381-390 of Total 1123