The analog input type (temperature/voltage/current) and offset/gain can be set for each channel. More Details >>
- No:24902
- Release Date:2019/04/15 11:31
- Category: MELSEC-F Series , Analog Control
-
RS-485 connection between QJ71C24N and an external device
Short between SDA and RDA and between SDB and RDB, and then connect them to + (Data-A) and - (Data-B) on the external device. More Details >>
- No:22986
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Causes to why SD1286 does not turn on during socket communication of LCPU
Check the following. - Whether the external device specifies the port number of the corresponding connection to the L series CPU. - In the TCP fixed-length... More Details >>
- No:22787
- Release Date:2018/09/03 17:30
- Update:2018/09/22 11:51
- Category: MELSEC-L Series
-
Detecting the connection between a built-in Ethernet port QCPU and hub
You can check the connection to the hub with bit 10 of the special register SD1288. When bit 10 of the SD1288 is on, the QCPU is in connection with the hub. More Details >>
- No:22712
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
SD memory cards used for Q24DHCCPU-V
Mitsubishi Electric's SD memory cards, which can be installed into Q24DHCCPU-V, are shown below. - NZ1MEM-2GBSD (memory capacity: 2Gbytes) - NZ1MEM-4GBSD (... More Details >>
- No:22711
- Release Date:2018/09/03 17:29
- Update:2018/09/22 08:58
- Category: MELSEC-Q Series
-
Q series device data held in the case of a power failure
The data in the devices assigned to Latch (1) or Latch (2) in the "Device Setting" window ([PLC Parameter] -> [Device Setting] window) is held when a pow... More Details >>
- No:22638
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:37
- Category: MELSEC-Q Series
-
Fixed scan execution type (program setting item)
A fixed scan execution type program is a program executed at specified time intervals. This type of programs, unlike interrupt programs, can be interrupted i... More Details >>
- No:22617
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
GX Works2's compatibility with Monitor (write mode)
From version 1.62Q, GX Works2 supports Monitor (write mode). Pressing Shift+F4 allows an online change. More Details >>
- No:22612
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:18
- Category: MELSEC-Q Series
-
Updating to the 64-bit Windows 7 version of GX Works2
The message is displayed because the version of the CD does not support the 64-bit version. Execute the installation procedure in the condition. More Details >>
- No:22513
- Release Date:2018/09/03 17:28
- Update:2018/09/20 13:38
- Category: MELSEC-Q Series
-
When the block number of the file register (R) is saved and stored, the overhead time becomes 35.9 [us]. When the number of the file register is not saved o... More Details >>
- No:22465
- Release Date:2018/09/03 17:28
- Update:2018/09/19 11:57
- Category: MELSEC iQ-R Series