Communication between CPUs via built-in Ethernet port in LCPU
The following communication methods are available between the built-in Ethernet ports in the L series CPUs.- Simple PLC communication function- Socket commun... More Details >>
- No:22746
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
NTP support by the SNTP function of LCPU with built-in Ethernet port
NTP and SNTP are compatible. Therefore, an NTP server can be used for clock setting. More Details >>
- No:22744
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
How to suppress the instability of digital-converted output values
(1) Use separate cables for the AC control circuit and the external input signals of an analog input module to avoid the influence of the AC side surges an... More Details >>
- No:22709
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:11
- Category: MELSEC-Q Series
-
Deleting GX Developer when installing GX Works2
GX Developer does not need deleting when GX Works2 is installed. More Details >>
- No:22670
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
How to use the database function of the MELSEC iQ-R series
The database function manages tabular data including product information and production information as a database in a programmable controller. <... More Details >>
- No:22476
- Release Date:2018/09/03 17:28
- Update:2018/09/19 14:44
- Category: MELSEC iQ-R Series
-
I/O numbers of a MELSEC iQ-R series I/O combined module (RH42C4NT2P)
An input and output use a single I/O number. (This is the same as QH42P.) When you replace a module that uses serial I/O numbers (e.g. QX41Y41P) with this m... More Details >>
- No:22471
- Release Date:2018/09/03 17:28
- Update:2018/09/19 13:57
- Category: MELSEC iQ-R Series
-
Regarding how to generate a false error
There is no function to generate a false error. For example, if operand (s2): divisor is set to "0" in the division command and the command is executed, err... More Details >>
- No:44610
- Release Date:2024/11/28 16:11
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding Selecting a mapping pattern for PDO communication
On the FX5-CCLGN-MS, select "3rd Transmit PDO Mapping" and "3rd Revive PDO Mapping." The 3rd mapping pattern corresponds to the profile position mode (pp), ... More Details >>
- No:44477
- Release Date:2024/07/02 19:06
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding setting up encrypted communication (TLS) for FX5-ENET
In GX Works3, set the FX5-ENET module parameters from Basic Settings - External Device Configuration Settings. In the "Ethernet Configuration" screen, selec... More Details >>
- No:40050
- Release Date:2023/08/25 08:48
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding FX5-ENET/IP parameter settings
You will need the EtherNet/IP Configuration Tool for FX5-ENET/IP. Download the tool from the FA site. More Details >>
- No:39302
- Release Date:2023/01/12 16:53
- Category: MELSEC iQ-F Series , Network/Communication