FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
Regarding Circuit Blocks that cannot be written with Online Program Change.
HIOEN/DHIOEN instructions cannot be written with Online Program Change. In addition, circuit blocks containing positioning instructions or network instructio... More Details >>
- No:44354
- Release Date:2024/03/27 15:47
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding Bus Conversion Module Differences
The FX5-CNV-BUS is an additional cable type. ・Used when the FX5-CNV-BUS previous module is an expansion cable type module. The FX5-CNV-BUSC is an a... More Details >>
- No:44353
- Release Date:2024/03/27 15:49
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding connector conversion module differences
The FX5-CNV-IF is an additional cable type. ・FX5U/FX5UJ CPU Modules are supported. ・Used to connect an extension connector type module to an extension ca... More Details >>
- No:44351
- Release Date:2024/03/27 15:45
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding using the connector of the CPU Module
The input/output cables used in the FX3GC and FX3UC basic units can be diverted to the FX5UC CPU Module (connector type). More Details >>
- No:44350
- Release Date:2024/03/27 15:44
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding Boot Operation procedures
The boot operation function is configured and executed from the GX Works3 parameter settings as follows. (1) Open the boot configuration screen. From the... More Details >>
- No:44348
- Release Date:2024/03/27 15:29
- Category: MELSEC iQ-F Series , CPU Module
-
Regarding simultaneous execution of the MQTT communication function
The MQTT communication function cannot publish and subscribe at the same time. A program for the MQTT communication function is created using FB, but it c... More Details >>
- No:44345
- Release Date:2024/03/27 15:25
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding cable diversion to FX5-2HC/ES
The cable cannot be used because the connector shape is different, so change the wiring. FX5-2HC/ES is a spring clamp terminal block, and FX3U-2HC is a MIL-... More Details >>
- No:44337
- Release Date:2024/03/20 13:26
- Category: MELSEC iQ-F Series , High-Speed Counter
-
Regarding Free Mail Service with Email Function
Free mail services that have been verified to work with the email function are Gmail and Yahoo! It will be an email. Use the encryption function (TLS) to us... More Details >>
- No:40058
- Release Date:2023/08/25 10:22
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding QoS, Retain, Will, and Clean Session Functions for MQTT Communications
The QoS, Retain, Will, and Clean Session functions of the MQTT communication function can not be configured in buffer memory. Module FB: M+FX5ENET. QoS ca... More Details >>
- No:40053
- Release Date:2023/08/25 09:21
- Category: MELSEC iQ-F Series , Network/Communication
-
Regarding the Number of Sending Addresses for Email function
The FX5-ENET module parameter of GX Works3 can send up to 10 messages and the module FB can send up to 256 characters at a time. By entering multiple email ... More Details >>
- No:40052
- Release Date:2023/08/25 10:23
- Category: MELSEC iQ-F Series , Network/Communication
641-650 of Total 976