Making transparent connections using GX Developer
Set as follows in the Transfer Setup window. - Select "USB" for "PC side I/F". - Select "CPU Module" for "PLC side I/F" and check "via GOT (direct couple... More Details >>
- No:22640
- Release Date:2018/09/03 17:29
- Update:2018/09/21 11:39
- Category: MELSEC-Q Series
-
Simulation function not started
The simulation function utilizes the standard TCP/IP communication provided by Microsoft Corporation. A communication capability of software of another make... More Details >>
- No:22631
- Release Date:2018/09/03 17:29
- Update:2018/09/21 10:45
- Category: MELSEC-Q Series
-
GX Works2's compatibility with Monitor (write mode)
From version 1.62Q, GX Works2 supports Monitor (write mode). Pressing Shift+F4 allows an online change. More Details >>
- No:22612
- Release Date:2018/09/03 17:29
- Update:2018/09/20 18:18
- Category: MELSEC-Q Series
-
GX Works2's compatibility with the A series modules
GX Developer is automatically launched when A series is selected as a new project in GX Works2.For the A series modules, use GX Developer. More Details >>
- No:22594
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Local devices are devices which can be independently used for each program.When multiple independent programs are executed, using local devices allows progra... More Details >>
- No:22531
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Index modifier of the bit device in the FX3GC series
FX3GC series does not support the index modifier for the bit devices. FX3U/FX3UC series supports it. More Details >>
- No:25002
- Release Date:2019/04/23 10:39
- Category: MELSEC-F Series
-
SB/SW refresh device setting with CC-Link
SB/SW uses 512 points of refresh devices. More Details >>
- No:23081
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Data length for fixed buffer data communications by QJ71E71
The units of send data and receive data are shown below. - Fixed buffer data communications with the "Procedure Exist" control method: Words - Fixed buff... More Details >>
- No:23061
- Release Date:2018/09/03 17:31
- Update:2018/09/26 11:17
- Category: Network related products
-
Link data from communication error stations in a CC-Link network
The remote input RX of the master station and the remote input RX and remote output RY of local stations clear/hold the data from an error station according ... More Details >>
- No:23057
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Overall cable distance and station-to-station distance in CC-Link networks
The overall cable distance and station-to-station distance depend on the version and the transmission speed. Figure 1 shows the case with Ver.1.10-compatibl... More Details >>
- No:23028
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:14
- Category: Network related products