FAQ
FAQAbout Products
- FAQ > Controllers > Programmable Controllers MELSEC
FAQ
Keyword Search
Programmable Controllers MELSEC
FAQ within [ Programmable Controllers MELSEC ]
-
If the OUT instruction using the device number of the latch target device exists in a sequence program, the latched data may be overwritten by execution of t... More Details >>
- No:24783
- Release Date:2019/02/27 16:16
- Category: MELSEC-F Series , Engineering Software , Main Unit
-
Terminal blocks for the MELSEC-F series
Whether the terminal block is removable or not differs depending on the series. Types of the terminal blocks for the MELSEC-F series main units are as follow... More Details >>
- No:24774
- Release Date:2019/02/27 15:34
- Category: MELSEC-F Series , Main Unit
-
External appearance of the F2-40BL
Some of the F2-40BL batteries installed to a programmable controller are mounted on the printed circuit board. The separately available F2-40BL batteries (sp... More Details >>
- No:24771
- Release Date:2019/02/27 15:17
- Category: MELSEC-F Series , Accessories
-
Differences between the AJ65SBTB1-16TE and AJ65SBTB1B-16TE1
The following shows the major differences. -AJ65SBTB1-16TE - 1-wire terminal block, 1-common type - Maximum load current: 0.1 A/point -Protection fu... More Details >>
- No:23083
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:16
- Category: Network related products
-
Assignment for connecting two CC-Link remote input modules (16-point type) (Remote net Ver.1 mode)
X devices will be assigned as follows. (With this setting, 32 points are occupied per station.) - Station No. 1: X100 to X11F -Station No. 2: X120 to X13... More Details >>
- No:23082
- Release Date:2018/09/03 17:31
- Update:2018/09/26 13:15
- Category: Network related products
-
How to check the error history of the QJ71C24N with GX Developer
You can check the error history in the module detailed information in the system monitor of GX Developer. More Details >>
- No:23064
- Release Date:2018/09/03 17:31
- Category: Network related products
-
To assure 32-bit data, "Network Range Assignment" of the control station must satisfy the following conditions.(1) The start device No. of LB is a multiple o... More Details >>
- No:23052
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Connecting terminating resistors for CC-Link communication
Connect terminating resistors to both ends of physical cables.A master station is not necessarily required to be connected to either end of its network. More Details >>
- No:23046
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Order in which a CC-Link master module and slave stations are connected
There is no restriction on the positions of a master station and slave stations where they are connected. (Stations are not required to be connected in order... More Details >>
- No:23041
- Release Date:2018/09/03 17:31
- Category: Network related products
-
Links with a CC-Link local station cannot be made
Check the following points. (1) CC-Link cables have been properly connected. (2) Station numbers and the transmission speed have been correctly set. (3)... More Details >>
- No:23033
- Release Date:2018/09/03 17:31
- Update:2018/09/26 10:22
- Category: Network related products