Versions of built-in Ethernet port LCPU compatible with SNTP function
The initial version and subsequent versions of L series CPU support the SNTP function. More Details >>
- No:22769
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Number of points used for I/O assignment of LCPU built-in I/O function
X00 to X0F and Y00 to Y07 are sorted for each function. For more details, refer to "MELSEC-L CPU Module User's Manual (Built-In I/O Function)". More Details >>
- No:22762
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
LCPU internal clock synchronization
Use the time setting function to synchronize the internal clock. More Details >>
- No:22755
- Release Date:2018/09/03 17:30
- Category: MELSEC-L Series
-
Use of a commercial SD memory card in L series logging function
Yes. Recommended products are listed in the technical bulletin FA-A-0078. More Details >>
- No:22753
- Release Date:2018/09/03 17:29
- Update:2018/10/03 16:25
- Category: MELSEC-L Series
-
Availability of step ladders for FX in L series
Step ladders are not available in LCPU. There is no alternative function. More Details >>
- No:22752
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
L63P compatibility with L series CPU packages
It is possible to remove L61P and use L63P. More Details >>
- No:22742
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
How to use L series extension modules
The extension module is used to configure the extension block when 10 modules or more are mounted to LCPU. Connect the branch module and the extension module... More Details >>
- No:22738
- Release Date:2018/09/03 17:29
- Category: MELSEC-L Series
-
Pulse width with which the QX42 recognizes all pulses
Maximum scan time (10 ms) + Response time (10 ms) = Pulse width with which the module recognizes all pulses (20 ms) More Details >>
- No:22720
- Release Date:2018/09/03 17:29
- Category: MELSEC-Q Series
-
Programing example of heating/cooling control
The following shows an example of heating/cooling control using split control. * For details, refer to the "Programmable Controllers MELSEC PROC... More Details >>
- No:22719
- Release Date:2018/09/03 17:29
- Update:2018/09/21 15:43
- Category: MELSEC-Q Series
-
Ethernet system configuration of a redundant system
The following figure shows the basic configuration. When a control system Ethernet module is faulty or disconnected, the system is switched at a disco... More Details >>
- No:22718
- Release Date:2018/09/03 17:29
- Update:2018/09/18 11:45
- Category: MELSEC-Q Series
911-920 of Total 976