Creating comments both in English and in Japanese
Create common comments and comments by program in respective languages.The device comments can be switched in [Options] -> [Tool]. More Details >>
- No:22546
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Turning OFF the power with the battery error occurring
It deletes the error history. More Details >>
- No:22545
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
Difference between QH42P and QX41Y41P
The difference is I/O numbers used for input and output (XY). QH42P uses the same I/O numbers both for input and output. QX41Y41P uses sequential I/O numbers... More Details >>
- No:22539
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
CPU modules supporting the serial communication function
CPU modules supporting the serial communication function are as follows. - Q00UJCPU,Q00UCPU,Q01UCPU - Q02UCPU 10102 or later (with GX Works2 1.15R or l... More Details >>
- No:22530
- Release Date:2018/09/03 17:28
- Update:2018/09/20 14:37
- Category: MELSEC-Q Series
-
Including GX Developer in GX Works2
Yes, it does.GX Developer can be installed along with the installation of GX Works2.For more details of the installation procedure, refer to GX Works2 Versio... More Details >>
- No:22506
- Release Date:2018/09/03 17:28
- Category: MELSEC-Q Series
-
The number of modules that can be synchronized is as follows. - In single CPU system configuration: 64 modules - In multiple CPU system configuration: 57 t... More Details >>
- No:22496
- Release Date:2018/09/03 17:28
- Update:2018/09/21 17:15
- Category: MELSEC iQ-R Series
-
Operations that can be performed with the MELSEC iQ-R series inter-module synchronization function
The inter-module synchronization function synchronizes the input or output timing of multiple I/O modules or intelligent function modules. The inter-... More Details >>
- No:22495
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:16
- Category: MELSEC iQ-R Series
-
You can synchronize the fixed scan communication cycle of the multiple CPU system function with the inter-module synchronization cycle of the inter-module s... More Details >>
- No:22494
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:12
- Category: MELSEC iQ-R Series
-
In the communication of the CC-Link IE Field Network synchronous communication function, you can synchronize the timing to send/receive data with the inter-... More Details >>
- No:22493
- Release Date:2018/09/03 17:28
- Update:2018/09/20 11:10
- Category: MELSEC iQ-R Series
-
Built-in Ethernet function setting window of MELSEC iQ-R series CPU modules
"Module Parameter" of the CPU module is the setting window. <Setting a built-in Ethernet port> [Navigation Window]-> [Parameter]-> [CPU Modul... More Details >>
- No:22488
- Release Date:2018/09/03 17:28
- Update:2018/09/20 09:40
- Category: MELSEC iQ-R Series