    When the heat sink is outside, since the heat sink and fan are not waterproof, you need to enclose them so that they are not exposed to the spray of water. More Details >>

    • No:21435
    • Release Date:2018/08/22 16:27
  • Influence on noise level

    By using the reactors 1 and 2 as well as the outside box supplied with the high power factor converter, while the noise may increase or decrease depending th... More Details >>

    • No:21559
    • Release Date:2018/08/22 16:28
  • Regenerative driving capability

    Continuous 100% regenerative braking torque is available for the rated capacity of the high power factor converter. (The same braking ability of the FR-A201 ... More Details >>

    • No:21563
    • Release Date:2018/08/22 16:28
  • Waveform improvement

    A reference sine wave signal is generated inside the high power factor converter, and transistors are configured and PWM switching is performed in the conver... More Details >>

    • No:21574
    • Release Date:2018/08/22 16:28
  • Brake unit selection

    1. The BU brake unit does not have the fault output.Multiple BU brake units can be connected in parallel.2. Power supply voltage 480 V- What resistance value... More Details >>

    • No:21930
    • Release Date:2018/08/22 16:30
  • EMC compliant filter terminal cover

    The SF1258 has the terminal cover.Although the SF1259 to SF1263 do not have the terminal covers and their terminals are bare, rubber tubes to cover them are ... More Details >>

    • No:21956
    • Release Date:2018/08/22 16:30
  • Control wire of FR-HC RDY signal

    The contact between the terminals RDY and SE is open collector output.Operation is:Normal: Non-conductiveFault: Conductive More Details >>

    • No:22017
    • Release Date:2018/08/22 16:30
  • FR-RC selection

    1. The 100% braking torque means the 100% motor rated torque. Do not consider the continuous regenerative driving based on the braking torque. Consider the r... More Details >>

    • No:22023
    • Release Date:2018/08/22 16:30
  • FR-BSF01 wiring

    The filtering effect is higher as the cable is wound more.However, if the cable is wound more than 4T on the inverter output side, since the inverter's outpu... More Details >>

    • No:22064
    • Release Date:2018/08/22 16:30
  • Installation method

    If multiple line noise filters are wound without clearance between them, the noise reduction effect corresponding to the number of filters cannot be obtained... More Details >>