What is the replacement of the FR-BOL?
We do not offer a replacement product for the FR-BOL (noise reduction reactor). Since the FR-A100E is a low-noise type inverter, the motor noise is suppresse... More Details >>
By using the reactors 1 and 2 as well as the outside box supplied with the high power factor converter, while the noise may increase or decrease depending th... More Details >>
1. As the reactor (FR-HCL) is connected when connecting the FR-HC, do not connect the FR-BAL. 2. The noise filter can be connected to the input side of the F... More Details >>
Yes. More Details >>
It is general type button battery (CR1216 × 1). More Details >>
For the 200 V class, the 7.5K, 15K, 30K, and 55K models are available. For the 400 V class, the 7.5K, 15K, 30K, and 55K models are available. Each requires t... More Details >>
To almost "1". (With load factor of 100%) More Details >>
Using a higher grade power factor imp...
Using a reactor under a load lighter than the rated capacity slightly spoils its effect in improving the power factor.Therefore, you should use a reactor wit... More Details >>
Fault output terminal load pattern
The fault output terminals A and C, and B and C of the power regeneration converter FR-RC are not capable of a micro load of 5 VDC±5%, 10 mA. The minimum loa... More Details >>
The whole system consists of the power supply, molded case circuit breaker, high power factor converter, inverter, and motor. The high power factor converter... More Details >>