  • Error of the communication option

    E.OP1 indicates the communication line error. E.1 indicates a hardware fault of the communication option. (It is judged as the hardware fault when the commun... More Details >>

    • No:20805
    • Release Date:2018/08/22 16:24
  • Resetting inverter after restoring from power failure

    When the programmable controller power is turned OFF while the inverter is in the PLC link operation mode, a communication error occurs and the inverter trip... More Details >>

    • No:21417
    • Release Date:2018/08/22 16:27
  • Digital input and maximum frequency

    1. Pr.1 and 18 limit the output to 120 Hz. Use Pr.18 to change the maximum frequency. 2. If you want to output the binary input as is, setting Pr.304 = 1 (Bi... More Details >>

    • No:22098
    • Release Date:2018/08/22 16:30
  • FR-A800 and Ethernet IP communication

    Yes. the options support it. By connecting the following communication option (built-in circuit board) manufactured and sold by HMS to the FR-A800 series, th... More Details >>

    • No:20823
    • Release Date:2018/08/22 16:24
  • CC-Link

    The corresponding bit (RYB) can be used when a function other than reset is assigned to the RES terminal, but it cannot be used as the reset function. Use RY... More Details >>

    • No:21142
    • Release Date:2018/08/22 16:26
  • Parameter writing via CC-Link

    Pr.133 can be written.Since the data code numbers of parameters are duplicate, target parameters are switched by link parameter extended setting.You can acce... More Details >>

    • No:21976
    • Release Date:2018/08/22 16:30
  • Plug-in options

    Up to three plug-in options can be mounted. More Details >>

    • No:21093
    • Release Date:2018/08/22 16:25
  • 12-bit digital input

    You can set both the BCD code and binary code inputs within the range from 0 to 400 Hz.You can set the bias and gain in 0.01 Hz units.For BCD input, when the... More Details >>

    • No:21945
    • Release Date:2018/08/22 16:30
  • Plug-in options

    You cannot reuse the plug-in option for the FREQROL-A200 and A100 series. You must use one of the following three plug-in options dedicated to the FREQROL-V2... More Details >>

    • No:21656
    • Release Date:2018/08/22 16:28
  • Plug-in options

    Use the plug-in option dedicated for the FR-A200EXECLLENT. The plug-in option for the FR-A200EXECLLENT cannot be used with the FR-A200. To avoid installing a... More Details >>

    • No:21634
    • Release Date:2018/08/22 16:28