  • Communication option

    You can remove the parameter unit FR-PU02 and install the FR-CU01 there. However, since the interface for the parameter unit is used, the communication speed... More Details >>

    • No:21625
    • Release Date:2018/08/22 16:28
  • Do you have a sample program for 485 communication?

    We do not offer a sample program for the programmable controller. Refer to the Instruction Manual and create the program by yourself. More Details >>

    • No:21522
    • Release Date:2018/08/22 16:28
  • Countermeasure against noise on input side

    In general, the line noise filter (FR-BLF) is used against the power supply noise. The AC reactor also works. As other countermeasures:- Use a metal conduit ... More Details >>

    • No:21517
    • Release Date:2018/08/22 16:28
  • How can I calculate the processing torque from the measured power?

    You can calculate the torque from the power.  From the general equation: Pout = ωn × TT = (Pout × τ)/ωnPout: Measured valueωn: Actual motor shaft angular fre... More Details >>

    • No:21475
    • Release Date:2018/08/22 16:27
  • Countermeasure against harmonics

    When the high power factor converter is installed, you can use the conversion coefficient of K5 = 0 for calculation. In accordance with the harmonic suppress... More Details >>

    • No:21398
    • Release Date:2018/08/22 16:27
  • Dynamic brake

    It is the brake function that consumes the rotational energy by heat and stops the motor immediately by short-circuiting between the motor terminals through ... More Details >>

    • No:21066
    • Release Date:2018/08/22 16:25
  • Parameter list

    The setting memo of the parameter list seal is not provided with the FR-A500 Instruction Manual. More Details >>

    • No:21485
    • Release Date:2018/08/22 16:27
  • MM-CF

    DC90V More Details >>

    • No:20965
    • Release Date:2018/08/22 16:25
  • MM-EF/EFS

    Yes, the 7.5 kW or lower motor can be used for belt drive hanging and direct connection. Note that the standard models of 11 kW or higher motor are dedicated... More Details >>

    • No:20962
    • Release Date:2018/08/22 16:25
  • Which is the recommended digital counter?

    We recommend the following digital counter: (Connect it between the terminals FM and SD.) Manufacturer: KOYO ELECTRONICS INDUSTRIES CO., LTD.Model: TC-41 More Details >>

    • No:21469
    • Release Date:2018/08/22 16:27