  • Communication option

    You can remove the parameter unit FR-PU02 and install the FR-CU01 there. However, since the interface for the parameter unit is used, the communication speed... More Details >>

    • No:21625
    • Release Date:2018/08/22 16:28
  • Countermeasure against noise on input side

    In general, the line noise filter (FR-BLF) is used against the power supply noise. The AC reactor also works. As other countermeasures:- Use a metal conduit ... More Details >>

    • No:21517
    • Release Date:2018/08/22 16:28
  • Vector motor

    The constant-torque motor and vector motor are the induction motors, which consist of the stator core, gap, and rotor core. For the constant-torque motor, th... More Details >>

    • No:21378
    • Release Date:2018/08/22 16:27
  • How can I calculate the processing torque from the measured power?

    You can calculate the torque from the power.  From the general equation: Pout = ωn × TT = (Pout × τ)/ωnPout: Measured valueωn: Actual motor shaft angular fre... More Details >>

    • No:21475
    • Release Date:2018/08/22 16:27
  • Built-in reactor

    The reactor built in the FREQROL-A201 series is intended to stabilize operation of the converter circuit and differs from the FR-BAL. Note that when performi... More Details >>

    • No:21421
    • Release Date:2018/08/22 16:27
  • Replacement of the SF-JR with the SF-PR

    Since the SF-PR is more efficient compared to the SF-JR, the resistance will decrease and the load current will increase. Check the following two points when... More Details >>

    • No:20949
    • Release Date:2018/08/22 16:25
  • Can you provide the CAD data?

    The CAD data is found on the member's page of Mitsubishi Electric FA Global Website. More Details >>

    • No:22091
    • Release Date:2018/08/22 16:30
  • Surge voltage of 400 V inverter

    1. Since the voltage resistance of the standard motor is not improved, it is recommended to use an "insulation-enhanced motor".If you are using an insulation... More Details >>

    • No:21957
    • Release Date:2018/08/22 16:30
  • No load current value of motor

    No load current for each power supply voltage is as follows:- Approximately 15.5 A for 200 VAC 60 Hz- Approximately 21.7 A for 220 VAC 60 HzThe current is es... More Details >>

    • No:21534
    • Release Date:2018/08/22 16:28
  • MM-EF/EFS

    Since the standard bearing is adopted for the belt drive models, a creep may occur and the motor bracket may wear out. More Details >>

    • No:20964
    • Release Date:2018/08/22 16:25