  • Which is the recommended digital counter?

    We recommend the following digital counter: (Connect it between the terminals FM and SD.) Manufacturer: KOYO ELECTRONICS INDUSTRIES CO., LTD.Model: TC-41 More Details >>

    • No:21469
    • Release Date:2018/08/22 16:27
  • MM-EF/EFS

    Yes, the 7.5 kW or lower motor can be used for belt drive hanging and direct connection. Note that the standard models of 11 kW or higher motor are dedicated... More Details >>

    • No:20962
    • Release Date:2018/08/22 16:25
  • Countermeasure against inverter noise

    You can attach the following filters to the inverter input side:- Line noise filter (FR-BLF, FR-BSF01)- Radio noise filter (FR-BIF)  While it is a good idea ... More Details >>

    • No:21528
    • Release Date:2018/08/22 16:28
  • Selection

    It is not completely recommended to use F700P because the starting torque at low speed of the hydraulic pump may be larger than that of the normal pump. Sele... More Details >>

    • No:21126
    • Release Date:2018/08/22 16:26
  • Insulation level of the MM-EFS

    F class (155 deg C) More Details >>

    • No:20809
    • Release Date:2018/08/22 16:24
  • No load current value of motor

    No load current for each power supply voltage is as follows:- Approximately 15.5 A for 200 VAC 60 Hz- Approximately 21.7 A for 220 VAC 60 HzThe current is es... More Details >>

    • No:21534
    • Release Date:2018/08/22 16:28
  • Tuning

    Setting the tuning data without tuning makes no difference. The tuning method of the FR-A700 is different from that of V500. Tuning can be performed by setti... More Details >>

    • No:21139
    • Release Date:2018/08/22 16:26
  • Influence on external measurement device

    It is considered that malfunction of the measurement device is due to noise. Check the noise propagation route since the countermeasure depends on it. Some c... More Details >>

    • No:22100
    • Release Date:2018/08/22 16:30
  • Countermeasure against harmonics

    When the high power factor converter is installed, you can use the conversion coefficient of K5 = 0 for calculation. In accordance with the harmonic suppress... More Details >>

    • No:21398
    • Release Date:2018/08/22 16:27
  • Vector motor

    The constant-torque motor and vector motor are the induction motors, which consist of the stator core, gap, and rotor core. For the constant-torque motor, th... More Details >>

    • No:21378
    • Release Date:2018/08/22 16:27