  • Do you have a sample program for 485 communication?

    We do not offer a sample program for the programmable controller. Refer to the Instruction Manual and create the program by yourself. More Details >>

    • No:21522
    • Release Date:2018/08/22 16:28
  • How can I calculate the processing torque from the measured power?

    You can calculate the torque from the power.  From the general equation: Pout = ωn × TT = (Pout × τ)/ωnPout: Measured valueωn: Actual motor shaft angular fre... More Details >>

    • No:21475
    • Release Date:2018/08/22 16:27
  • FR-FS2

    The description has been deleted because there is no industrial pressure ventilation fan that can be used for the FR-FS2, due to the production termination o... More Details >>

    • No:21064
    • Release Date:2018/08/22 16:25
  • MM-EF/EFS

    Yes, the 7.5 kW or lower motor can be used for belt drive hanging and direct connection. Note that the standard models of 11 kW or higher motor are dedicated... More Details >>

    • No:20962
    • Release Date:2018/08/22 16:25
  • Regeneration unit

    You can reuse the brake units used with the FR-A series, including the FR-RC power regeneration converter, FR-BU, and BU brake unit. You can also use the hig... More Details >>

    • No:21658
    • Release Date:2018/08/22 16:28
  • Insulation level of the MM-EFS

    F class (155 deg C) More Details >>

    • No:20809
    • Release Date:2018/08/22 16:24
  • Compatibility with Y-△ motor and others

    1. You can connect them using △ connection. 2. No problem with connecting four Y-△ motors. (Connect all four motors using △ connection.) (Note that the inver... More Details >>

    • No:21487
    • Release Date:2018/08/22 16:27
  • Parameter list

    The setting memo of the parameter list seal is not provided with the FR-A500 Instruction Manual. More Details >>

    • No:21485
    • Release Date:2018/08/22 16:27
  • Countermeasure against harmonics

    When the high power factor converter is installed, you can use the conversion coefficient of K5 = 0 for calculation. In accordance with the harmonic suppress... More Details >>

    • No:21398
    • Release Date:2018/08/22 16:27
  • CAD data

    They are not available. More Details >>

    • No:21138
    • Release Date:2018/08/22 16:26