FAQ within [ Others ]

41-50 of Total 53

prev 5 / 6page next
  • Certificate for special tax reduction for first year facilities

    The special tax reduction for first year facilities is the taxation system for promoting investment in the reform of the energy supply. The required certific... More Details >>

    • No:21514
    • Release Date:2018/08/22 16:28
  • Number of inverters that can be connected to a 20 A branch circuit breaker

    The basic idea is the same, but the total capacity should be 3.7 kW. (The maximum capacity is also 3.7K.) More Details >>

    • No:21508
    • Release Date:2018/08/22 16:28
  • FR-FS2

    The description has been deleted because there is no industrial pressure ventilation fan that can be used for the FR-FS2, due to the production termination o... More Details >>

    • No:21064
    • Release Date:2018/08/22 16:25
  • MM-EF/EFS

    Since the standard bearing is adopted for the belt drive models, a creep may occur and the motor bracket may wear out. More Details >>

    • No:20964
    • Release Date:2018/08/22 16:25
  • Influence on external measurement device

    It is considered that malfunction of the measurement device is due to noise. Check the noise propagation route since the countermeasure depends on it. Some c... More Details >>

    • No:22100
    • Release Date:2018/08/22 16:30
  • Countermeasure against inverter noise

    You can attach the following filters to the inverter input side:- Line noise filter (FR-BLF, FR-BSF01)- Radio noise filter (FR-BIF)  While it is a good idea ... More Details >>

    • No:21528
    • Release Date:2018/08/22 16:28
  • Vector motor

    The constant-torque motor and vector motor are the induction motors, which consist of the stator core, gap, and rotor core. For the constant-torque motor, th... More Details >>

    • No:21378
    • Release Date:2018/08/22 16:27
  • Parameter list

    The setting memo of the parameter list seal is not provided with the FR-A500 Instruction Manual. More Details >>

    • No:21485
    • Release Date:2018/08/22 16:27
  • No load current value of motor

    No load current for each power supply voltage is as follows:- Approximately 15.5 A for 200 VAC 60 Hz- Approximately 21.7 A for 220 VAC 60 HzThe current is es... More Details >>

    • No:21534
    • Release Date:2018/08/22 16:28
  • Surge voltage of 400 V inverter

    1. Since the voltage resistance of the standard motor is not improved, it is recommended to use an "insulation-enhanced motor".If you are using an insulation... More Details >>

    • No:21957
    • Release Date:2018/08/22 16:30

41-50 of Total 53