  • Specifications

    It can be driven by connecting single-phase 200 V to the terminals R and S. In this case, the load current must be one-third or less of the inverter rated cu... More Details >>

    • No:21282
    • Release Date:2018/08/22 16:26
  • Stop-on-contact control of the FR-E700

    The stop-on-contact control becomes invalid when the start command is turned OFF during the stop-on-contact control and the machine is decelerated to a stop ... More Details >>

    • No:20822
    • Release Date:2018/08/22 16:24
  • Torque control

    Torque control cannot be performed with the FR-E700 series. It is available with the FR-A700 and FR-V500 series. More Details >>

    • No:21279
    • Release Date:2018/08/22 16:26
  • CC-Link

    Yes, but the optional kit (FR-A7NC E kit) is necessary. More Details >>

    • No:21877
    • Release Date:2018/08/22 16:29