It is Pr.125 (Terminal 2 frequency setting gain frequency). Adjust the slope with C4 (903) (Terminal 2 frequency setting gain) as necessary. More Details >>
It is not switched. The frequency at the fault saved in the faults history is always displayed in frequency [Hz]. More Details >>
The total wiring length is as follows: 100 m + (20 m × 5) = 200m. More Details >>
Configure the same setting as the SF-HRCA. Configure the same setting as the SF-HRCA. A700, E700, D700, F700PJ: Pr.71 = 50F700P, F700: Pr.71 = 1 (Reference) ... More Details >>
Reverse rotation prevention selection
Yes, it does. When the inverter is coasting in the reverse direction, it starts in the reverse direction and switches to the forward rotation after a deceler... More Details >>
If Pr 27 is not set, the operation starts at the speed of RL. More Details >>
The time from when the frequency command is applied until it is reflected on the operation of the motor is different. For the analog input, the multiple anal... More Details >>
The length within 30 m is recommended. When the wiring length is long, signals may not be received accurately due to the increased inductance. More Details >>
The Radio Act applies to the products used for the purpose of the radio waves. Inverters are used for motor drive and thus out of the scope. More Details >>
Safety stop function of the FR-D700/F...
It is recommended to install the magnetic contactor on the input side of the inverter for safety. The category 3 can be satisfied without installing it. More Details >>