FAQ


FAQAbout Products

- FAQ > Drive Products > Inverters-FREQROL > FREQROL-A700
FAQ
Keyword Search
FAQ within [ FREQROL-A700 ]
-
It is not activated because the function itself is disabled. More Details >>
- No:21137
- Release Date:2018/08/22 16:26
-
Check the setting value of Pr.37 (Speed display). When the machine speed is set, Pr.811 is disabled. Change the setting to the rotation speed. More Details >>
- No:21161
- Release Date:2018/08/22 16:26
-
Install the resistor between the terminals PC and OH. More Details >>
- No:21160
- Release Date:2018/08/22 16:26
-
The leakage current is 1 mA because the circuit constant in the EMC filter of A720-0.4K and 0.75K are different. More Details >>
- No:21120
- Release Date:2018/08/22 16:26
-
The initial value of Pr.872 is set to "1" (Valid) because the A701 have regeneration unit built-in and an overvoltage may occur when the regenerative operati... More Details >>
- No:20945
- Release Date:2018/08/22 16:25
-
It is protected not by observing the temperature directly, but by estimating it from the current value, output frequency, and carrier frequency. More Details >>
- No:20871
- Release Date:2018/08/22 16:24
-
The following reasons are possible. - The signal of Z phase does not exist. (It is not returned normally.) - The setting of Pr.359 encoder rotation direction... More Details >>
- No:21162
- Release Date:2018/08/22 16:26
-
The brake unit operates when the bus voltage exceeds the brake operation voltage. More Details >>
- No:21272
- Release Date:2018/08/22 16:26
-
"E.OSD" occurs when the rotation speed is not decreased for one second despite the start command (STF, STR) is turned OFF. More Details >>
- No:21159
- Release Date:2018/08/22 16:26
-
Setting the tuning data without tuning makes no difference. The tuning method of the FR-A700 is different from that of V500. Tuning can be performed by setti... More Details >>
- No:21139
- Release Date:2018/08/22 16:26
1-10 of Total 352