- FAQ > Drive Products > Inverters-FREQROL > FREQROL-A024
FAQ
Keyword Search
FAQ within [ FREQROL-A024 ]
-
You can use it with the FR-A200 (E) and FR-A100 (E) series. (Note) Use the connection cable (option). You cannot use it with the FR-Z and FR-U series (except... More Details >>
- No:21615
- Release Date:2018/08/22 16:28
-
Difference in purpose from FR-A200 series
Reference of proper use of each series is as follows: - A024: When balance between size, performance, and cost is important. - A200: When system configuratio... More Details >>
- No:21610
- Release Date:2018/08/22 16:28
-
Do noise and leakage current increase?
During non-low-noise operation (initial setting) with the carrier frequency of 1 kHz, both noise and leakage current levels are almost same as the Z024 serie... More Details >>
- No:21606
- Release Date:2018/08/22 16:28
-
Yes. (However, you need to use the parameter unit connection cable FR-CBL (option).) More Details >>
- No:21604
- Release Date:2018/08/22 16:28
-
Can I connect it to high power factor converter?
It can be connected to an inverter that supports the high power factor converter FR-HC. (It cannot be connected to conventional inverters.) How to identify i... More Details >>
- No:21602
- Release Date:2018/08/22 16:28
-
Providing thermal protection is better for your safety. When the brake transistor explodes, the brake transistor alarm (E.BE) is output. Consider a counterme... More Details >>
- No:21397
- Release Date:2018/08/22 16:27
-
Installation of new serial communication unit FR-CU03
Remove the parameter unit FR-PU03 and install there. (The installation dimensions of the FR-CU03 are the same as the FR-PU.) You can read and write parameter... More Details >>
- No:21617
- Release Date:2018/08/22 16:28
-
Can I use the parameter unit FR-PU02?
Yes, but functions are partially limited. (The FR-PU02 cannot demonstrate its full ability. The FR-PU01 cannot be used.) To use the parameter unit FR-PU02, u... More Details >>
- No:21613
- Release Date:2018/08/22 16:28
-
Can a brake resistor or brake unit be connected?
You can connect them to the FR-A024 inverter 0.4 to 3.7K. (You cannot connect them to 0.1K and 0.2K.)Available brake resistor options include the FR-ABR high... More Details >>
- No:21612
- Release Date:2018/08/22 16:28
-
Number of inverters that can be connected to a 20 A branch circuit breaker
The basic idea is the same, but the total capacity should be 3.7 kW. (The maximum capacity is also 3.7K.) More Details >>
- No:21508
- Release Date:2018/08/22 16:28