Providing thermal protection is better for your safety. When the brake transistor explodes, the brake transistor alarm (E.BE) is output. Consider a counterme... More Details >>
- No:21397
- Release Date:2018/08/22 16:27
-
Can a brake resistor or brake unit be connected?
You can connect them to the FR-A024 inverter 0.4 to 3.7K. (You cannot connect them to 0.1K and 0.2K.)Available brake resistor options include the FR-ABR high... More Details >>
- No:21612
- Release Date:2018/08/22 16:28
-
How much low-speed torque can be output?
By choosing the General-purpose magnetic flux vector control and slip compensation function, you can output torque of 150% or more at 1 Hz (200% or more at 3... More Details >>
- No:21618
- Release Date:2018/08/22 16:28
-
Can I use the parameter unit FR-PU02?
Yes, but functions are partially limited. (The FR-PU02 cannot demonstrate its full ability. The FR-PU01 cannot be used.) To use the parameter unit FR-PU02, u... More Details >>
- No:21613
- Release Date:2018/08/22 16:28
-
The FR-AU03 is a dedicated product for the FR-A024. Although it cannot be attached directly to other inverters (FR-A200 and FR-Z, FR-U series), it can be use... More Details >>
- No:21603
- Release Date:2018/08/22 16:28
-
Yes. (However, you need to use the parameter unit connection cable FR-CBL (option).) More Details >>
- No:21604
- Release Date:2018/08/22 16:28
-
Pr.59 is available in the products manufactured in October 1995 or later. Therefore, it cannot be read from the products manufactured before October 1995. More Details >>
- No:21170
- Release Date:2018/08/22 16:26
-
Can I replace the cooling fan alone?
The fan of the FR-A024 cannot be replaced by the customer. Mitsubishi Electric System & Service will replace it, so contact us to order it. More Details >>
- No:22001
- Release Date:2018/08/22 16:30
-
The FM output is the 1440 Hz, 1 mA pulse train output at full scale. You can input to the programmable controller if it has a pulse train input. A68AD does n... More Details >>
- No:21439
- Release Date:2018/08/22 16:27
-
Do noise and leakage current increase?
During non-low-noise operation (initial setting) with the carrier frequency of 1 kHz, both noise and leakage current levels are almost same as the Z024 serie... More Details >>
- No:21606
- Release Date:2018/08/22 16:28