FAQ within [ FREQROL-A024 ]
-
The following seven models are available for the 200 V class: 0.1K, 0.2K, 0.4K, 0.75K, 1.5K, 2.2K, and 3.7K The following five models are available for the 4... More Details >>
- No:21621
- Release Date:2018/08/22 16:28
-
Providing thermal protection is better for your safety. When the brake transistor explodes, the brake transistor alarm (E.BE) is output. Consider a counterme... More Details >>
- No:21397
- Release Date:2018/08/22 16:27
-
Can a brake resistor or brake unit be connected?
You can connect them to the FR-A024 inverter 0.4 to 3.7K. (You cannot connect them to 0.1K and 0.2K.)Available brake resistor options include the FR-ABR high... More Details >>
- No:21612
- Release Date:2018/08/22 16:28
-
The FM output is the 1440 Hz, 1 mA pulse train output at full scale. You can input to the programmable controller if it has a pulse train input. A68AD does n... More Details >>
- No:21439
- Release Date:2018/08/22 16:27
-
Since the inverter power supply uses the single-phase input, you cannot use a 0.75K inverter with a 0.6 kW motor to draw the maximum ability of the motor. To... More Details >>
- No:21470
- Release Date:2018/08/22 16:27
-
You can vary the carrier frequency within the range of 0.7 to 14.5 kHz, and it is initially set to 1 kHz that generates low noise and leakage current. You ca... More Details >>
- No:21607
- Release Date:2018/08/22 16:28
-
How many inverters can I connect using the communication unit?
Since the communication unit conforms to the EIA Standard RS-485, up to 32 inverters can be connected. (Transmission format: Multidrop link, total wiring len... More Details >>
- No:21616
- Release Date:2018/08/22 16:28
-
Do noise and leakage current increase?
During non-low-noise operation (initial setting) with the carrier frequency of 1 kHz, both noise and leakage current levels are almost same as the Z024 serie... More Details >>
- No:21606
- Release Date:2018/08/22 16:28
-
Many geared motors cannot continuously operate at low speed (for example, slower than 6 Hz) due to grease viscosity.If the motor you are using is of this typ... More Details >>
- No:22028
- Release Date:2018/08/22 16:30
-
How much low-speed torque can be output?
By choosing the General-purpose magnetic flux vector control and slip compensation function, you can output torque of 150% or more at 1 Hz (200% or more at 3... More Details >>