- FAQ > Drive Products > Inverters-FREQROL > FREQROL-E500
FAQ
Keyword Search
FAQ within [ FREQROL-E500 ]
-
Inverter drive of 400 V class motor
When the wiring between the inverter and motor is long, surge voltage occurs at the terminal of the motor.This surge voltage deteriorates insulation of the m... More Details >>
- No:21926
- Release Date:2018/08/22 16:30
-
Parameters not covered in manual are displayed
Pr.168 indicates the inverter software version.Pr.169 indicates the inverter software subversion history. These two parameters are only used by the manufactu... More Details >>
- No:21532
- Release Date:2018/08/22 16:28
-
Since the inverter displayed "0.00" instead of an error when the inverter speed dropped to 0 Hz and stopped by holding the winding machine by hand, it is con... More Details >>
- No:21492
- Release Date:2018/08/22 16:27
-
"Err" is displayed when STF signal turns ON
Possible causes are:1. The reset signal (RES) is ON. 2. The built-in CPU is not working properly due to contact faults of the inverter parts. Check the exte... More Details >>
- No:21484
- Release Date:2018/08/22 16:27
-
Frequent occurrences of OL means that the inverter is overloaded. Since the inverter can go faulty if it is constantly overloaded, you need to take a counter... More Details >>
- No:21430
- Release Date:2018/08/22 16:27
-
The RS485 communication is explained in the FREQROL-E500 Instruction Manual. This Instruction Manual is published on the member's page of Mitsubishi Electric... More Details >>
- No:21426
- Release Date:2018/08/22 16:27
-
When the wire between the 400 V inverter and motor is long (20 m or longer), surge voltage occurs momentarily. This voltage is as two or more times as the DC... More Details >>
- No:21404
- Release Date:2018/08/22 16:27
-
The current monitor displays the average value of the three-phase current. The three-phase voltage is not incorporated for the voltage monitor. The output vo... More Details >>
- No:21376
- Release Date:2018/08/22 16:27
-
Operation panel extension cable
Yes, you can use the 10BASE-T cable (straight) with the E500. More Details >>
- No:22085
- Release Date:2018/08/22 16:30
-
When consuming the regenerative power with the brake resistor, the brake transistor is triggered at a certain voltage to make the brake resistor use the rege... More Details >>
- No:22074
- Release Date:2018/08/22 16:30
21-30 of Total 85