  • Operation panel

    Be sure to use the FR-E5P to mount the operation panel.This is because the board is bare on the back of the operation panel and a dedicated connector is requ... More Details >>

    • No:22030
    • Release Date:2018/08/22 16:30
  • Regenerative brake resistor

    The brake resistor is not built in the inverter. Purchase the optional resistor and connect it to the inverter.Inverter only (without resistor)Continuous reg... More Details >>

    • No:21989
    • Release Date:2018/08/22 16:30
  • Connecting operation panel to enclosure

    To connect the operation panel to the enclosure, use the parameter unit connection cable FR-CB201, FR-CB203, or FR-CB205. The maximum cable length is 5 m. No... More Details >>

    • No:21542
    • Release Date:2018/08/22 16:28
  • FR-E520 7.5 kW model

    The outline dimensions of the FR-E520-7.5K are 180W×260H×170D. More Details >>

    • No:21521
    • Release Date:2018/08/22 16:28
  • Frequency setting

    Ensure that the inverter is in the PU operation mode and stopped, change the following parameters: 1. Read Pr.923 (Built-in frequency setting potentiometer g... More Details >>

    • No:21416
    • Release Date:2018/08/22 16:27
  • Parameter unit display

    Setting Pr.37 to the machine speed at 60 Hz switches the frequency monitor to the rotations per minute monitor.Note that the speed setting must be input in a... More Details >>

    • No:22072
    • Release Date:2018/08/22 16:30
  • Analog output

    The FM output is 0 to 8 VDC pulse. More Details >>

    • No:22039
    • Release Date:2018/08/22 16:30
  • Analog signal resolution

    The internal processing speed is not published. The analog input specifications are as follows: FR-A500???1/4000FR-E500???1/1000MR-H???1/4000 More Details >>

    • No:21550
    • Release Date:2018/08/22 16:28
  • Inverter input power supply

    Square wave input is not recommended since it can cause failures (for example, damage the diode bridge). More Details >>

    • No:22106
    • Release Date:2018/08/22 16:31
  • Operation panel extension cable

    Yes, you can use the 10BASE-T cable (straight) with the E500. More Details >>

    • No:22085
    • Release Date:2018/08/22 16:30