FAQ within [ FREQROL-E500 ]

71-80 of Total 84

prev 8 / 9page next
  • Permissible brake duty

    When consuming the regenerative power with the brake resistor, the brake transistor is triggered at a certain voltage to make the brake resistor use the rege... More Details >>

    • No:22074
    • Release Date:2018/08/22 16:30
  • Control method

    1. Can I set the frequency by the external potentiometer when multi-speed signal is 0 (nothing is input)?-> It is possible by using the external operation... More Details >>

    • No:21990
    • Release Date:2018/08/22 16:30
  • FR-E520 7.5 kW model

    The outline dimensions of the FR-E520-7.5K are 180W×260H×170D. More Details >>

    • No:21521
    • Release Date:2018/08/22 16:28
  • Usage

    1. Changing frequency to 0 Hz(1) Set Pr.8 (Deceleration time) to 0 second.If the load is large, the stall prevention function may work to lengthen decelerati... More Details >>

    • No:22019
    • Release Date:2018/08/22 16:30
  • Control circuit power supply

    If the MC on the input side is shut off using the fault output of the FR-E500, the inverter's fault records are left in the faults history. More Details >>

    • No:22096
    • Release Date:2018/08/22 16:30
  • Operation panel

    Be sure to use the FR-E5P to mount the operation panel.This is because the board is bare on the back of the operation panel and a dedicated connector is requ... More Details >>

    • No:22030
    • Release Date:2018/08/22 16:30
  • Operation frequency

    I cannot answer clearly because the load is unknown. The operation cycle of operating for 10 seconds and stopping for 10 seconds is OK, but it is questionabl... More Details >>

    • No:21474
    • Release Date:2018/08/22 16:27
  • Alarm output signal when using CC-Link

    The RX7 output signal is the same as the signals for NO, NC, and transfer contact output.You can change the contents of this output signal using Pr.192.Pr.19... More Details >>

    • No:22008
    • Release Date:2018/08/22 16:30
  • Built-in potentiometer and current input switching control

    For setting the frequency, you cannot switch between the operation panel potentiometer and current input from an external source.To switch between the extern... More Details >>

    • No:21985
    • Release Date:2018/08/22 16:30
  • External thermal overheat

    Take the following countermeasure:1. If the thermal trips in low-speed operation, trips can be avoided, depending on the external thermal relay operation cha... More Details >>

    • No:21954
    • Release Date:2018/08/22 16:30

71-80 of Total 84