If the MC on the input side is shut off using the fault output of the FR-E500, the inverter's fault records are left in the faults history. More Details >>
- No:22096
- Release Date:2018/08/22 16:30
-
Ensure that the inverter is in the PU operation mode and stopped, change the following parameters: 1. Read Pr.923 (Built-in frequency setting potentiometer g... More Details >>
- No:21416
- Release Date:2018/08/22 16:27
-
An inverter is used to rotate a motor but it cannot be used to detect whether the belt is broken or not. However, the magnitude of the load will change when ... More Details >>
- No:21387
- Release Date:2018/08/22 16:27
-
Since the inverter displayed "0.00" instead of an error when the inverter speed dropped to 0 Hz and stopped by holding the winding machine by hand, it is con... More Details >>
- No:21492
- Release Date:2018/08/22 16:27
-
I cannot answer clearly because the load is unknown. The operation cycle of operating for 10 seconds and stopping for 10 seconds is OK, but it is questionabl... More Details >>
- No:21474
- Release Date:2018/08/22 16:27
-
1. Can I set the frequency by the external potentiometer when multi-speed signal is 0 (nothing is input)?-> It is possible by using the external operation... More Details >>
- No:21990
- Release Date:2018/08/22 16:30
-
Parameters not covered in manual are displayed
Pr.168 indicates the inverter software version.Pr.169 indicates the inverter software subversion history. These two parameters are only used by the manufactu... More Details >>
- No:21532
- Release Date:2018/08/22 16:28
-
Indication of potentiometer on operation panel
The potentiometer on the operation panel is initially calibrated so that the maximum indication is slightly over 60 Hz with the potentiometer turned to the m... More Details >>
- No:21427
- Release Date:2018/08/22 16:27
-
Output specification between FM and SD
The output signal across FM and SD is pulse output. The output frequency and number of pulses of the output signal across FM and SD are proportional. However... More Details >>
- No:21384
- Release Date:2018/08/22 16:27
-
Connecting operation panel to enclosure
To connect the operation panel to the enclosure, use the parameter unit connection cable FR-CB201, FR-CB203, or FR-CB205. The maximum cable length is 5 m. No... More Details >>
- No:21542
- Release Date:2018/08/22 16:28