FAQ within [ FREQROL-V200 ]
-
Driving 200 V motor by 400 V inverter
A 400 V inverter does not operate when 200 V is supplied to it, therefore the motor does not rotate. A 200 V motor can be rotated by a 400 V inverter, howeve... More Details >>
- No:21446
- Release Date:2018/08/22 16:27
-
Angular velocity change control
The inverter itself does not have a function to detect the rotation angle and change the velocity accordingly. Therefore, to implement required control, it i... More Details >>
- No:22086
- Release Date:2018/08/22 16:30
-
Just by adding this option, encoder pulses connected to the inverter or option are output.You can also divide the pulse train output. More Details >>
- No:22062
- Release Date:2018/08/22 16:30
-
Cycle operation mode, continuous operation mode, torque characteristic selection
When using a motor with an encoder by performing auto tuning, you need to choose the operation mode or continuous operation mode depending on the application... More Details >>
- No:21661
- Release Date:2018/08/22 16:28
-
12 models of FREQROL-V200 vector inverters each for the 200 V and 400 V classes from 1.5K to 45K. 9 models of SF-VR vector control dedicated motors each for ... More Details >>
- No:21657
- Release Date:2018/08/22 16:28
-
You cannot reuse the plug-in option for the FREQROL-A200 and A100 series. You must use one of the following three plug-in options dedicated to the FREQROL-V2... More Details >>
- No:21656
- Release Date:2018/08/22 16:28
-
I want to drive other manufacturer's motor with PG
You can drive the motor with the FR-V240E-5.5K. However, the following conditions apply: - You need to perform auto tuning because the motor's circuit consta... More Details >>
- No:21539
- Release Date:2018/08/22 16:28
-
Unwinding using vector inverter
1. Torque control automatically adjust the speed so that the instructed torque value is maintained. This means that the speed is not controlled. (However, yo... More Details >>
- No:21420
- Release Date:2018/08/22 16:27
-
Power factor improving effect by option
Installing the high power factor converter brings the power factor improving effect of 99% or higher.Therefore, when the high power factor converter is used,... More Details >>
- No:22020
- Release Date:2018/08/22 16:30
-
Use Pr.17 (Input terminal assignment) to assign MRS to the terminals DI1, DI2, and DI3. More Details >>
- No:21937
- Release Date:2018/08/22 16:30