Start main contents

Factory Automation

FAQ

Factory Automation

FAQAbout Products

  • Font Size
  • S
  • M
  • L

FAQ within [ FREQROL-V200 ]

41-50 of Total 52

prev 5 / 6page next
  • Applicable motors

    In addition to the dedicated motor (SF-VR series), the SF-JR series motor with an encoder can be used. You can also use a standard motor by combining it with... More Details >>

    • No:21653
    • Release Date:2018/08/22 16:28
  • Use of general-purpose servo motor

    You can operate it by adjusting the motor constant by the auto tuning function. (Note that the same characteristics as operated by the servo amplifier MR-VA ... More Details >>

    • No:21652
    • Release Date:2018/08/22 16:28
  • Small capacity vector inverter dedicated motor

    We offer 5.5 kW or higher SF-VR dedicated motors and do not offer small capacity (3.7 kW or lower) motors. If you need small capacity (1.5 kW to 3.7 kW), use... More Details >>

    • No:21648
    • Release Date:2018/08/22 16:28
  • Geared motor

    We do not offer a geared motor. More Details >>

    • No:21647
    • Release Date:2018/08/22 16:28
  • Torque control accuracy

    Since the torque control accuracy is influenced by change of motor temperature:- Standard product???±5% (at 75 deg C) ±0.5%/deg C of rated torque- Combinatio... More Details >>

    • No:21645
    • Release Date:2018/08/22 16:28
  • Explosion countermeasure

    We do not offer an explosion-proof type of vector inverter. More Details >>

    • No:21644
    • Release Date:2018/08/22 16:28
  • Encoder signal output

    It can be output by attaching the plug-in option FR-VPA, FR-VPB, or FR-VPC. Note that the output format depends on the option type. FR-VPA: Open collector ou... More Details >>

    • No:21643
    • Release Date:2018/08/22 16:28
  • Can I change the carrier frequency?

    You can change it by changing the setting of Pr.72 (PWM frequency selection). Setting range of Pr.72: 0, 1, 2, 3, 4, 5, 6 (Initial setting is "6".) (The smal... More Details >>

    • No:21640
    • Release Date:2018/08/22 16:28
  • Static torque

    When a vector inverter is used for position control, the servo lock works when it is stopped. When the start signal (STF or STR) is turned ON, the servo lock... More Details >>

    • No:21502
    • Release Date:2018/08/22 16:28
  • Speed fluctuation

    I use the dedicated motor SF-VR with the same capacity as the inverter. 1. Load fluctuationSpeed fluctuation ratio with the load fluctuation 0 to 100% is:Wit... More Details >>

    • No:21490
    • Release Date:2018/08/22 16:27

41-50 of Total 52

Inquiries