FAQ within [ Drive Products ]
-
Inverter installation interchange attachment
Use the FR-A5AT02 as the intercompatibility attachment when upgrading from the FR-A220-3.7K to FR-A540-3.7K. More Details >>
- No:22095
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-A500
-
Frequency does not rise with blower
Our suggestion is to adjust the following parameters:1. Set Pr.14 = 0. If the V/F pattern for variable-torque load (Pr.14 = 1) is used, the current may incre... More Details >>
- No:22060
- Release Date:2018/08/22 16:30
- Category: Inverters-FREQROL , FREQROL-F500
-
If you have already set other parameters necessary for tuning (Pr.9, Pr.71, Pr.80, Pr.81, Pr.83, and Pr.84), press the MODE button to return to the frequency... More Details >>
- No:21750
- Release Date:2018/08/22 16:29
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-A700
-
Switching between external operation and NET operation
You can switch between external operation and NET operation by turning ON/OFF the terminal X66 (RM). You can switch while Pr.79 (Operation mode) is set to "6... More Details >>
- No:21688
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-E700 , FREQROL-D700 , FREQROL-A700 , FREQROL-F700 , FREQROL-F700P , FREQROL-F700PJ
-
Do you have an explosion-proof type?
We offer the FR-A200E-based pressure-resistant explosion-proof motor driving inverter FR-B series. This series have been certified in the explosion-proof tes... More Details >>
- No:21630
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A200
-
General-purpose magnetic flux control
Almost same control method. This control also performs vector calculation and divides the inverter's output current into an excitation current and into a tor... More Details >>
- No:21620
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , FREQROL-A024
-
Can a single potentiometer operate two speed controller?
A single potentiometer cannot operate two speed controller. Reason: Since the control circuit and main circuit of the SC-A speed controller are not insulated... More Details >>
- No:21578
- Release Date:2018/08/22 16:28
- Category: Inverters-FREQROL , SC-A
-
Automatic overload control of inverter
The inverter has the current limit function. This automatically controls the frequency so that the preset current value may not be exceeded. (Note that the m... More Details >>
- No:21409
- Release Date:2018/08/22 16:27
- Category: Inverters-FREQROL , FREQROL-A500 , FREQROL-F500 , FREQROL-E500 , FREQROL-S500
-
For the FR-F800 series, in addition to the conventional Optimum excitation control, Advanced optimum excitation control with the improved starting torque is ... More Details >>
- No:21072
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , FREQROL-F800
-
It is the brake function that consumes the rotational energy by heat and stops the motor immediately by short-circuiting between the motor terminals through ... More Details >>
- No:21066
- Release Date:2018/08/22 16:25
- Category: Inverters-FREQROL , Others
91-100 of Total 1368